Page 104 - Vessel Sanitation Program 2018 Construction Guidelines
P. 104

VSP 2018 Construction Guidelines



                                       following factor: One person per 19 liters [5 gallons] per minute of
                                       recirculation flow.)

                                Pictograms may replace words, as appropriate or available.

                                It is advisable to post additional cautions and concerns on signs.

                                See section 31.3 for safety signs specific to BABY-ONLY WATER
                                FACILITIES and section 32.1.3 for safety signs specific to WHIRLPOOL
                                SPAS and SPA POOLS.


                          28.3.1.1      Children’s Recreational Water Facility
                                        For signs in children’s RECREATIONAL WATER FACILITIES,
                                        include the exact wording “TAKE  CHILDREN ON FREQUENT
                                        BATHROOM BREAKS” or “TAKE CHILDREN ON FREQUENT
                                        TOILET BREAKS.” This is in addition  to the basic
                                        RECREATIONAL WATER FACILITY safety sign.


                   28.4  Life-Saving Equipment

                       28.4.1   Location
                                A rescue or shepherd’s hook and an APPROVED floatation device must be
                                provided at a prominent location (visible from the full perimeter of the pool)  at
                                each RECREATIONAL WATER FACILITY that has a depth of 1 meter (3
                                feet) or  greater. These devices must be mounted in a manner that allows for
                                easy access during an emergency.
                                   •  The pole of the shepherd’s hook must be long enough to reach the
                                       center of the deepest portion of the pool from the side plus 0.6 meters  (2
                                       feet). It must be light, strong, and nontelescoping with rounded
                                       nonsharp ends.
                                   •  The flotation device must have an attached rope that is at least two-
                                       thirds of the maximum pool width.


               29.0  Recirculation and Filtration Systems

                   29.1  Skim Gutters
                          Where skim gutters are installed, ensure that the maximum fill level of the
                          RECREATIONAL WATER FACILITY is  to the skim gutter level.

                   29.2  Overflows
                          Ensure that overflows are directed by gravity to the compensation or make-up tank
                          for filtration and DISINFECTION. Alternatively, overflows may be directed to the
                          RECREATIONAL WATER FACILITY drainage system. If the overflow is
                          connected to another drainage system,  provide an AIR GAP or a DUAL SWING
                          CHECK VALVE between the two.