VSP 2018 Construction Guidelines



                                The shut-off control must operate similarly when the UV DISINFECTION
                                system is not operating within acceptable parameters.


                   31.7  Baby-Only Water Facility Pump Room

                       31.7.1   Discharge
                                All recirculated water discharged to waste must be through a visible indirect
                                connection in the pump room.

                       31.7.2   Flow Meter
                                A flow meter must be installed in the return line before HALOGEN injection.
                                The flow meter must be accurate to within 10% of actual flow.

               32.0  Additional Requirements for Whirlpool Spas and Spa Pools
                       WHIRLPOOL SPAS that are similar in design and construction to public WHIRLPOOL
                       SPAS but located for the sole use of an individual cabin or groups of cabins must comply
                       with the public WHIRLPOOL SPA requirements if the WHIRLPOOL SPA has either of
                       the following features:
                          •  Tub capacity of more than four individuals.
                          •  Location outside of cabin or cabin balcony.

                   32.1  Overflow System
                          Design the overflow system for WHIRLPOOL SPAS so the water level is maintained.


                   32.2  Temperature Control
                          Provide a temperature control mechanism to prevent the temperature from exceeding
                          40ºC (104ºF).


                   32.3  Safety Sign
                          In addition to the RWF safety sign in section 28.3, install a sign at each
                          WHIRLPOOL SPA and SPA POOL entrance listing precautions and risks associated
                          with the use of these facilities. At a minimum, include cautions against use by the
                          following:
                              •  Individuals who are immunocompromised.
                              •  Individuals on medication or who have underlying medical conditions, such as
                                 cardiovascular disease, diabetes, or high or low blood pressure.
                              •  Children, pregnant women, and elderly persons.

                          Additionally, include caution against exceeding 15 minutes of use.

                   32.4  Drainage System
                          For WHIRLPOOL SPAS, provide a line in the drainage system to allow these
                          facilities to be drained to the GRAY WATER, TECHNICAL WATER, or other
                          wastewater holding  system through an indirect connection or a DUAL SWING
                          CHECK VALVE. This does not include the BLACK WATER system.