Page 117 - Vessel Sanitation Program 2018 Construction Guidelines
P. 117
VSP 2018 Construction Guidelines
(22 inches) above the deck.
• Provide hot and cold POTABLE WATER to all handwashing sinks.
• Equip handwashing sinks to provide water at a temperature not to
exceed 43°C (110°F) during use.
• Provide handwashing facilities that include a soap dispenser, paper
towel dispenser or air dryer, and a waste receptacle. Install soap and
paper towel dispensers close to the sink and near to the height of the
sink.
34.1.2 Toilet Rooms
Toilet rooms must be provided in CHILD ACTIVITY CENTERS. Provide one
toilet for every 25 children or fraction thereof, based on the maximum capacity
of the center. The toilet rooms must include items noted in sections 34.1.2.1
through 34.1.2.6.
34.1.2.1 Child-Sized Toilets
CHILD-SIZED TOILETS with a maximum height of 280 millimeters
(11 inches) (including the toilet seat) and toilet seat opening no greater
than 203 millimeters (8 inches).
34.1.2.2 Handwashing Facilities
Provide hot and cold POTABLE WATER to all handwashing sinks.
Equip handwashing sinks to provide water at a temperature not to
exceed 43°C (110°F) during use.
Install handwashing sinks with a maximum height of 560 millimeters
(22 inches) above the deck.
Provide handwashing facilities that include a soap dispenser and paper
towel dispenser or air dryer, and a waste receptacle.
34.1.2.3 Storage
Provide storage for gloves and wipes.
34.1.2.4 Waste Receptacle
Provide an airtight, washable, waste receptacle.
34.1.2.5 Self-Closing Doors
Provide self-closing toilet room exit doors.
34.1.2.6 Sign
Provide a sign with the exact wording “WASH YOUR HANDS AND
ASSIST THE CHILDREN WITH HANDWASHING AFTER
HELPING THEM USE THE TOILET.” The sign should be in English
and can also be in other languages.
101