VSP 2018 Construction Guidelines
millimeter x 584 millimeter (18 inch x 23 inch) body-blocking element as set forth in
ASME A112.19.8M.
Bulkhead: A dividing wall covering an area constructed from several panels, also
known as the visible part of the lining.
Certified data security features: Features that ensure the values recorded by the
data logger cannot be manipulated by the user.
Child activity center: A facility for child-related activities where children under the
age of 6 are placed to be cared for by vessel staff.
Children’s pool: A pool that has a depth of 1 meter (3 feet) or less and is intended
for use by children who are toilet trained.
Child-size toilet: Toilets whose toilet seat height is no more than 280 millimeters
(11 inches) and the toilet seat opening is no greater than 203 millimeters (8 inches).
Cleaning locker: A room or cabinet specifically designed or modified for storage of
cleaning EQUIPMENT such as mops, brooms, floor-scrubbing machines, and
cleaning chemicals.
Continuous pressure (CP) backflow prevention device: A device generally
consisting of two check valves and an intermediate atmospheric vent that has been
specifically designed to be used under conditions of continuous pressure (greater
than 12 hours out of a 24-hour period).
Coved (also coving): A concave surface, molding, or other design that eliminates the
usual angles of 90° or less at deck junctures (Figures 3, 4, and 5).
10