ORDERING INFORMATION

Description            Size              Material    Sensor Only                                                                                           Hot Tap Options
                                                     Standard Options
Sensor Only.     3” - 12” = TX110        Brass = B                                                                                            Bidirectional = -03
                12” - 40” = TX210        316 SS = S  Brass Adapter Fitting 2” NPT = -02           Brass Adapter 1 ½” BSP = -23                Micropower Pickup = -04
                                                     SS Adapter Fitting 2” NPT = -02              SS Adapter 1 ½” BSP = -24                   Standard Power, LMI 4-pin Connector = -06
                        Hot Tap                      Bidirectional = -03                          Old Style Adapter 1 ½” NPT = -35            Standard Power, Seametrics Control Connector = -07
                 3” - 12” = TX150                    Micropower Pickup = -04                      Immersible = -40                            316 SS Valve Assembly = -08
                12” - 40” = TX250                    Standard Power, LMI 4-pin Connector = -06    12” Extension (210/250 Series Only) = -72   Immersible = -40
                                                     Stnd Power, Seametrics Ctrl Connector = -07  Roytronics Series-A 5-Pin Connector = -106  12” Extension (210/250 Series Only) = -72
                                                                                                                                              Roytronics Series-A 5-Pin Connector = -106

Description            Size              Material    FT400 Series (External Power) Mounted on Sensor                                                       Hot Tap Options
                                                                                 Standard Options
Rate & total    FT430 3” - 12” = TX113   Brass = B                                                                                            Bidirectional = -03
indicator with  FT430 12” - 40” = TX213  316 SS= S   Brass Adapter Fitting 2” NPT = -02           Old Style Adapter 1 ½” NPT = -35            316 SS Valve Assembly = -08
pulse & 4-20    FT440 3” - 12” = TX115               SS Adapter Fitting 2” NPT = -02              Non-resettable Total = -64                  No Valva Assembly = -09
mA output,      FT440 12” - 40” = TX215              Bidirectional = -03                          12” Extension (210/250 Series Only) = -72   Tamper Evident Kit = -32
externally                                           Brass Adapter 1 ½” BSP = -23                 Dual Relay Output = -98                     Old Style Adapter = -35
powered                   Hot Tap                    SS Adapter 1 ½” BSP = -24                    Hinged Display Cover = -126                 Non-resettable Total = -64
(FT400 Series)  FT430 3” - 12” = TX153               Tamper Evident Kit = -32                                                                 12” Extension (210/250 Series Only) = -72
mounted on      FT430 12” - 40” = TX253                                                                                                       Dual Relay Output = -98
the sensor.     FT440 3” - 12” = TX155                                                                                                        Hinged Display Cover = -126
                FT440 12” - 40” = TX255

Description            Size              Material    AO55 Mounted on Sensor                                                                                Hot Tap Options
                                                              Standard Options
Blind 4-20 mA    3” - 12” = TX112        Brass = B                                                                                            Bidirectional = -03
analog trans-   12” - 40” = TX212        316 SS = S  Brass Adapter Fitting 2” NPT = -02           SS Adapter 1 ½” BSP = -24                   Standard Power, LMI 4-pin Connector = -06
mitter (AO55)                                        SS Adapter Fitting 2” NPT = -02              Old Style Adapter 1 ½” NPT = -35            316 SS Valve Assembly = -08
mounted on              Hot Tap                      Bidirectional = -03                          12” Extension (210/250 Series Only) = -72   No Valva Assembly = -09
the sensor.      3” - 12” = TX152                    Standard Power, LMI 4-pin Connector = -06    Roytronics Series-A 5-Pin Connector = -106  12” Extension (210/250 Series Only) = -72
                12” - 40” = TX252                    Brass Adapter 1 ½” BSP = -23                                                             Roytronics Series-A 5-Pin Connector = -106

Description            Size              Material    FT450 (Battery Power) Mounted on Sensor                                                               Hot Tap Options
                                                                                  Options
Rate & total     3” - 12” = TX117        Brass = B                                                                                            Bidirectional = -03
indicator with  12” - 40” = TX217        316 SS = S  Brass Adapter Fitting 2” NPT = -02           Tamper Evident Kit = -32                    316 SS Valve Assembly = -08
pulse & 4-20                                         SS Adapter Fitting 2” NPT = -02              Old Style Adapter 1 ½” NPT = -35            No Valva Assembly = -09
mA output,              Hot Tap                      Bidirectional = -03                          Non-Resettable Total = -64                  Tamper Evident Kit = -32
battery pow-     3” - 12” = TX157                    Brass Adapter 1 ½” BSP = -23                 12” Extension (210/250 Series Only) = -72   Non-resettable Total = -64
ered (FT450)    12” - 40” = TX257                    SS Adapter 1 ½” BSP = -24                    Hinged Display Cover = -126                 12” Extension (210/250 Series Only) = -72
mounted on                                                                                                                                    Hinged Display Cover = -126
the sensor.

Description            Size              Material    DL76 Mounted on Sensor                                                                                Hot Tap Options
                                                                     Options
Data log-        3” - 12” = TX116        Brass = B                                                                                            Bidirectional = -03
ger (DL76)      12” - 40” = TX216        316 SS = S  Brass Adapter Fitting 2” NPT = -02           SS Adapter 1 ½” BSP = -24                   316 SS Valve Assembly = -08
mounted on                                           SS Adapter Fitting 2” NPT = -02              Tamper Evident Kit = -32                    No Valva Assembly = -09
the sensor.             Hot Tap                      Bidirectional = -03                          Old Style Adapter 1 ½” NPT = -35            Tamper Evident Kit = -32
                 3” - 12” = TX116                    Brass Adapter 1 ½” BSP = -23                                                             12” Extension (210/250 Series Only) = -72
                12” - 40” = TX216

Description            Size              Material    PD10 Mounted on Sensor                                                                                Hot Tap Options
                                                                     Options
Pulse            3” - 12” = TX118        Brass = B                                                                                            Bidirectional = -03
Divider (PD10)  12” - 40” = TX218        316 SS = S  Brass Adapter Fitting 2” NPT = -02           SS Adapter 1 ½” BSP = -24                   LMI Pump 4-pin Connector = -06
mounted on                               PVC = P     SS Adapter Fitting 2” NPT = -02              Old Style Adapter 1 ½” NPT = -35            316 SS Valve Assembly = -08
the sensor.     Hot Tap                              Bidirectional = -03                          10 Ft. Cable for LMI Connector = -37        No Valva Assembly = -09
                 3” - 12” = TX158                    LMI Pump 4-pin Connector = -06               Roytronics Series-A 5-Pin Connector = -106  10’ Cable for LMI Adapter = -37
                12” - 40” = TX258                    Brass Adapter 1 ½” BSP = -23                                                             12” Extension (210/250 Series Only) = -72
                                                                                                                                              Roytronics Series-A 5-Pin Connector = -106

*Consult factory for suitable applications **Requires appropriate fitting. † Total Units must be specified at time of order	

                                                                                                                                                                                          46
   54   55   56   57   58   59   60   61   62   63   64