Page 100 - final report_Neat
P. 100

upstanding
                                                                                    beam
                                                  Normal beam
















                                                If the ground level is low the traditional casting of
                                                beam does not allow lights to enter to the basement,
                                                but the use of Upstanding beam allows light passing
                                                to the basement





  Points to be remember in slab design
  • Proper cover of 10-12 mm should be
     maintained.
  • Spacing of top bars and bottom bars
     should be as mentioned in drawing.
  • Electrical layout before casting.                                         Crank portion
  • Crank length is 0.1 ly, lx from the end of
     the beam.
  • Properly     placement    of   chair   bars   to
     prevent collapsing and touching of upper
     cage    reinforcement     and    lower    cage
     reinforcement to one another
                                                                                       Chair bars

  Bending of stirrups on
  site























                                              Placing of rebars with
                                              proper marking.


          79