Page 30 - Handbook GEOTEKNIK_Final_Neat
P. 30

Typical JKR’s Termination Criteria for Borehole & Rock                                                                              Field Testing


                   Termination          Building         Embankment          Cut Area           River           Bridge                             Field Works     Description/       Limitation                             Photos
                     Criteria                                                                                                                                        Purpose
                SPT N-value        Five (5) times      Three (3) times    Three (3) times   Three (3) times   Seven (7)
                                   SPT N-value = 50   SPT N-value = 30   SPT N-value =     SPT N-value =     times SPT N-
                                                                          50               30                value = 50
                                                                                                                                                   4. Trial Pits     to obtain     for shallow
                                                                                                                                                                    bulk sample      depth up to
                                                                                                                                                                    for soil         approximately
                       Or*                Or*                 Or*               and              Or*              Or*                                               classification   3.0m


                Termination        45.0                30.0               At least 5m      30.0              50.0
                Depth (m)                                                 from Formation
                                                                          Level

                    Table 5: Typical JKR’s Termination Criteria for Borehole & Rock          Notes:* Whichever comes first


                                          Rock Type                                        Min. Core Length
                 Igneous rocks (granite) & bore depth < 24m or Recovery ratio R/                 4.5m                                                                                                   Figure 8: Bulk Sample for Trial Pit
                 r < 50%
                 Igneous rocks, bore depth > 24m                                                 3.0m
                 Shale/schist/slate/sandstone                                                    6.0m
                 Recovery ratio R/r < 50%
                 Shale/schist/slate/sandstone                                                    3.0m
                 Recovery ratio R/r > 50%
                 Limestone R/r > 50% and no cavity                                               6.0m
                 Limestone R/r < 50% or with cavity                                           9m – 21m
                 Other rocks R/r > 50%                                                           4.5m
                 Other rocks R/r < 50%                                                           6.0m
                                  Min. core size should be 52mm diameter (NMLC or HMLC or equivalent)

       14  PUBLIC WORKS DEPARTMENT MALAYSIA                                                                                                                                                                                      GEOTECHNICAL ENGINEERING HANDBOOK  15
   25   26   27   28   29   30   31   32   33   34   35