ELECTRICAL COMPONENTS


              Clutch Pressure Control (PC) Solenoids 2, 3, 4 & 5:
              The clutch pressure control (PC) solenoids 2 and 3 are nor-    CONTROL
                                                                                            COIL
              mally-high PC solenoids and are identical to the line PC sole-  PRESSURE    ASSEMBLY
              noid (page 46). The clutch PC solenoids 4 and 5 are normally-  SUPPLY                HOUSING
              low and are the same as the TCC PC solenoid (page 45).  PRESSURE    EXHAUST
                                                                  (ACTUATOR
              The clutch PC solenoid 2 controls fluid flow to the 3-5 and  FEED LIMIT)
              reverse clutch regulator and 3-5 and reverse clutch boost valves.
              When commanded, the PC solenoid controls the flow of ex-
              haust fluid out of the solenoid to maintain a specific com-
              manded control pressure. This allows the TCM to control the                                 CONNECTOR
              apply and release of the 3-5 and reverse clutch.
                                                                  CLOSED END
              The clutch PC solenoid 3 controls fluid flow to the 4-5-6 clutch  FEATURE  O-RING  VARIABLE
              regulator and 4-5-6 clutch boost valves. When commanded, the       RESTRICTION
              PC solenoid controls the flow of exhaust fluid out of the sole-  NORMALLY-LOW PRESSURE CONTROL SOLENOID
              noid to maintain a specific commanded control pressure. This
              allows the TCM to control the apply and release of the 4-5-6
              clutch.                                                        CONTROL        COIL
                                                                            PRESSURE
                                                                                          ASSEMBLY
              The clutch PC solenoid 4 controls fluid flow to the 2-6 clutch  SUPPLY               HOUSING
                                                                  PRESSURE
              regulator valve. When commanded, the PC solenoid controls  (ACTUATOR  EXHAUST
              the flow of exhaust fluid out of the solenoid to maintain a  FEED LIMIT)
              specific commanded control pressure. This allows the TCM to
              control the apply and release of the 2-6 clutch.
              The clutch PC solenoid 5 controls fluid flow to the 1-2-3-4
              clutch regulator and 1-2-3-4 clutch boost valves. When com-                                 CONNECTOR
              manded, the PC solenoid controls the flow of exhaust fluid out  CLOSED END
              of the solenoid to maintain a specific commanded control pres-  FEATURE  O-RING  VARIABLE  SPRING
              sure. This allows the TCM to control the apply and release of      RESTRICTION
              the 1-2-3-4 clutch.
                                                                          NORMALLY-HIGH PRESSURE CONTROL SOLENOID

                    Clutch Pressure Control (PC) Solenoid Logic
                                                                                                          LINE
                                PC Sol 5 PC Sol 4 PC Sol 2 PC Sol 3                                       PS5 DRIVE 1-6
                    Gear                                                                             38
                                  N.L.    N.L    N.H.    N.H.                                    CBR1/C456 CL REG VALVE
                     Park         OFF    OFF     OFF     ON                  ACT FD LIM
                                                                   CBR1/C456                    39  EX      EX  37
                                                                   PRESSURE      PCS CBR1/456 CL    EX BF
                   Reverse        OFF    OFF     ON      ON        CONTROL
                                                                   SOLENOID 3                         CBR1/456 CL FD  CBR1 FDBK
                    Neutral       OFF    OFF     OFF     ON        N.H. ON
              Drive 1 Engine Braking  ON  OFF    OFF     ON
                                                                                                31
                   Drive 1        ON     OFF     OFF     OFF                                               CBR1/456 CL FD
                                                                                              456 CL BOOST VALVE
                   Drive 2        ON      ON     OFF     OFF
                                                                                                         EX
                   Drive 3        ON     OFF     ON      OFF
                   Drive 4        ON     OFF     OFF     ON
                   Drive 5        OFF    OFF     ON      ON                                    35R CL BOOST VALVE
                   Drive 6        OFF     ON     OFF     ON                                      40       EX
                                                                                                        35 REV CL FDBK
              Transmission Adapt Function:                                                             PS1
              Programming within the TCM also allows for automatic                        PCS 35 REV CL    35 REV CL
              adjustments in shift pressure that are based on the changing                         EX
              characteristics of the transmission components.  As the apply                     3-5 REV CL REGULATOR VALVE
              components within the transmission wear or change over time,                         47  46    EX
              shift time (the time required to apply a clutch) increases or          ACT FD LIM  48       ACT FD LIM
              decreases. In order to compensate for these changes, the TCM                           EX BF  35R FD
              adjusts the pressure commands to the various PC solenoids, to
              maintain the originally calibrated shift timing.  The automatic  ACT FD LIM  ACT FD LIM
                                                                  C35R
              adjusting process is referred to as “adaptive learning” and it is  PRESSURE
                                                                  CONTROL
                                                                  SOLENOID 2                                    1234 CL
              used to ensure consistent shift feel plus increase transmission  N.H. OFF  ACT FD LIM
              durability.  The TCM monitors the A/T ISS and the A/T OSS
                                                                                                        1234 CL BOOST VALVE
              during commanded shifts to determine if a shift is occurring too
                                                                                                             29
              fast (harsh) or too slow (soft) and adjusts the corresponding PC                                    EX
              solenoid  signal to maintain the set shift feel.                              EX  1234 CL
                                           456 CL                            ACT FD LIM  SHTL  1-2-3-4 CL REGULATOR VALVE  PCS 1234 CL  1234 CL FDBK
                                                  26 CL/1234 CL FD
                                       42       43                                  36  35  34  33  PS4  EX  50
                         ACT FD LIM
                                             2-6 CLUTCH REG
                                                                              EX BACKFILL         1234 CL FD
               CB26                   44                                                 1234 CL DFLT
               PRESSURE                 2-6 GAIN  EX BF  26 CL  PS3  EX  26 CL 41  C1234
               CONTROL       PCS 26 CL                            PRESSURE      PCS 1234 CL
               SOLENOID 4                                         CONTROL
                                                                  SOLENOID 5
               N.L. OFF                                    26 CL   N.L. OFF
                                                            Figure 43                                                47
   51   52   53   54   55   56   57   58   59   60   61