Page 97 - FanPedia - By Aerovent
P. 97

®
 FAN-PEDIA                                                                                             PROPELLERS
 Published by   AEROVENT.COM
 Aerovent                                                                                                         OVERVIEW
 ©2017


                                                                             “J” Propeller



                                                Propeller Overview
                                                •  Available in 7 & 9 blades
                                                •  Adjustable blade angles range from 30 to 50 degrees
                                                •  A hub cover helps streamline the air intake
                                                •  Right hand rotation only
                                                •  All sizes utilize a taper lock or trantorque bushing
                                                •  OLD STYLE: Blades & Hubs: Heat treated A356-T6
                                                    Aluminum (Standard Material)
                                                •  NEW STYLE: Blades 380 Die Cast Aluminum (Standard
 ADJUSTABLE PITCH PROPELLERS                        Material), Hub and Clamp Plate 319 Aluminum
                                                    (Standard Material)
 SIZES: 18” - 84” INCHES
 Rotation: RH Only                              Airflow Direction & Rotation
                                                •  Blades can be rotated 180 degrees if reversed airflow
                                                    is required (spinner cap/hub cover omitted)



                Intake
 NOTE - Rotation determined by
 viewing the propeller from the
 discharge side.                                                                                                           Standard Bore
                                                Discharge                                                                      PM Airflow


 Discharge
 STANDARD AIRFLOW
 (PM)
 air passes
 through Prop
 then over Motor  Intake                                                                                                      Reverse Bore
 aka: Hub on Intake                                                                                                             MP Airflow

                                                                                                                                                   49