Page 34 - DMcatalogue2017
P. 34

Low voltage AC drives

       ABB micro drives

       ACS150 – Dimensions, I/O and options






       Dimensions and weights
       Cabinet-mounted drives, wall mounted drives
                   IP20 (UL open)         NEMA 1
       Frame  H1  H2  H3  W  D  Weight H4  H5  W  D  Weight
       size  mm  mm mm  mm mm  Kg  mm mm mm  mm  Kg
       R0   169  202 239  70  142  1.1  257 280 70  142  1.5
       R1   169  202 239  70  142  1.3  257 280 70  142  1.5
   4   R2   169  202 239  105 142  1.5  257 282 105  142  1.5
       H1 = Height without fastenings and clamping plate       H1  H2  H3                 H4  H5
       H2 = Height with fastenings but without clamping plate
       H3 = Height with fastenings and clamping plate
       H4 = Height with fastenings and NEMA 1 connection box
       H5 = Height with fastenings, NEMA 1 connection box and hood
       W = Width
       D = Depth

                                                                         D
                                                                                   W             D

                                                                                                             W

       Options available                                     Typical I/O connections
       –     Input and output chokes
       –     Brake chopper resistors (all drives in the ACS150 range                        ACS150   I
        have integral chopper)                                                               SCR       DIP switch
                                                                                                       analogue Input
                                                                                              AI
       –  First environment EMC filters - footprint style    0 - 20 mA                       GND     U
                                                             Ground cable
       – Low leakage EMC filters < 30 mA leakage               screen at                     +10 V
       – FlashDrop - programming without power               sourcing end                    +24 V

       –   NEMA kit allows installations to be neater and provides                  start/   GND

                                                                                    stop
         mechanical support for glanded cables               0 - 10 V can       fwd/        DCOM
                                                             be used by
                                                                                             DI1
                                                             connecting pot     rev          DI2
                                                             to 10V, GND   Const. speed 1
                                                             and AI, DIP   Const. speed 2    DI3
                                                             switch to ‘u’                   DI4
                                                                          Change ramp
                                                                                             DI5
                                                                              All I/O shown          Fault
                                                             DI configuration NPN  as default  ROCOM
                                                             PNP is possible   settings. Can  RONC
                                                                              be configured  RONO
                                                                              to other set-ups.
       User interfaces                                       EMC filter grounding                Removable clip for brand
       The ACS150 has a simple user interface, consisting of I/O   screw (EMC)                   labelling
       connections and a fixed programming keypad. An integrated                                 Integrated interface
       speed control potentiometer is also provided.         Varistor grounding
                                                             screw (VAR)
                                                             Analogue input signal               FlashDrop connection
                                                             selector (U/I)
                                                                                                 Integrated potentiometer
                                                                                                 I/O connections
                                                             Input, brake resistor
                                                             and motor connections



       34  Drives and controls, motors and mechanical power transmission catalogue