Page 45 - +GF+ PPR Aquasystem Catalogue 2017_Neat
P. 45

Socket Fusion Installation


                                      Preparation








                                                            1. Fix heating bushes
                                                              Attach the heating bushes on the heating tool. Maximum
                                                              two set of bushes can be attached at the same time.








                                                            2. Check the Temperature
                                                              Once the socket fusion machine is turned on, set the
                                                              temperature on the electronic display which must
                                                              range between 255°C and 265°C. To ensure correct
                                                              temperature, regular calibration is recommended.







                                                            3. Clean the heating tools
                                                              After checking the temperature, wipe the heater bush
                                                              with a clean cloth. This process must be repeated after
                                                              each welding.







                                                            4. Cut the pipe
                                                              Cut the pipe at right angle; if necessary remove burrs
                                                              from inside. If necessary cut deformed or damaged
                                                              pipe ends of 5 cm.







                                                            5. Clean pipe & fitting
                                                              Clean the fittings sockets on the inside and the outer
                                                              wall of pipe (the presence of dust, grease or other
                                                              impurities can affect the fusion quality and lead to weak
                                                              jointing).
                                                                                                                           correct installation










                                                                                                                  | 43