Page 19 - 2006 HARLEY FLSTCI SERVICE MANUAL
P. 19
1.6
2
3
1 2
3 Figure 1-9. Starter Wires 5 Figure 1-10. Free Running Current Draw Test
Nut with washer (metric) Solenoid wire 4 Mounting flange Induction ammeter Battery terminal Relay terminal
4 Positive battery cable ring terminal Circuit breaker wire ring terminal
s0192x5x 1. 2. 3. 4. b0439x5x 1 1. Battery 2. 3. 4. 5.
TESTING ASSEMBLED STARTER
FREE RUNNING CURRENT Place starter in vise, using a clean shop towel to prevent Figure 1-10. Attach one heavy jumper cable (6 Connect to the starter mounting flange (1). Connect to negative (-) terminal of a fully charged Connect a second heavy jumper cable (6 gauge mini- Connect to positive (+) terminal of the battery (2). Place an inductive ammeter (3) over cable. Continue on to the battery terminal (4) on the starter solenoid. Connect a smaller jumper cable (14 gauge minimum). Connect to positive (+) terminal of the battery (2). Connect to solenoid relay terminal (5). Check ammeter reading. Ammeter s
scratches or other damage. battery (2). STARTER SOLENOID prevent damage to solenoid.
DRAW TEST See gauge minimum). a. b. mum). a. b. a. b. maximum. a. b. death or serious injury.
HOME 1. 2. 3. 4. 5. 1-14