Page 20 - 2006 HARLEY FLSTCI SERVICE MANUAL
P. 20

1-15




                                   Battery                                   Battery                                   Battery
                 Relay terminal                Figure 1-11. Test 1: Pull-In Test  Relay terminal  Figure 1-12. Test 2: Hold-In Test  Relay terminal  Figure 1-13. Test 3: Return Test  2006 Softail: Starting & Charging










                 Motor terminal                           Motor terminal                            Motor terminal



              b0161a5x                                 b0162a5x                                  b0163a5x













             SOLENOID PULL-IN TEST  separate test leads as follows:  Observe starter shaft.  properly.  solenoid.  SOLENOID HOLD-IN TEST  tery post instead.   Observe starter shaft.  ing properly.   SOLENOID RETURN TEST  Observe starter pinion.





                  See Figure 1-11. Using a 12 volt battery, connect three Solenoid housing to negative battery post. Solenoid motor terminal to negative battery post. Solenoid relay terminal to positive battery post. If starter shaft extends strongly, solenoid is working If starter shaft does not extend strongly, replace the  See  Figure 1-12. With test leads still connected in the manner specified in the previous  SOLENOID PULL-IN disconnect solenoid motor terminal/battery negative test lead (B) at negative battery post only; reconnect loose end of this test lead to positive bat-  If starter shaft remains extended, solenoid








          HOME   1.   a.   b.   c.   2.  a.   b.   1.  TEST,   2.  a.   b.      1.       2.  a.   b.
   15   16   17   18   19   20   21   22   23   24   25