Page 25 - 2006 HARLEY FLSTCI SERVICE MANUAL
P. 25
Battery negative cable MILLIAMPERES DRAW 1.0 0.5 0.5 3.0 3.0 0.5 20.0* 0.5
Ignition turned to OFF
Figure 1-17. Milliampere Draw Test Table 1-4. Milliampere Draw Test * Siren will draw for 2-24 hours from time motorcycle battery is connected and 0.05 milliamperes once siren battery is charged. For best results, dis-
12 VDC battery ITEM ECM (EFI models) TSM (non security models) TSSM (storage mode) Security Siren (optional) connect siren during milliampere draw test.
d0297x8x Speedometer TSSM (disarmed) TSSM (armed) Voltage regulator
Milliampere Draw Test NOTES Be sure accessories are not wired so they stay on at all times. This condition could drain battery completely if vehicle is parked for a long time. Check for this by con- necting ammeter between negative battery terminal and TSM/TSSM will continue to draw 16-25 mA for 30 sec- onds after ignition is turned OFF . Any disruption and reconnection of battery power, such as disconnecting the battery to place a meter in series, will cause TSM/TSSM to draw 16-25 mA for 30 seconds. On carbureted models, ignition control module (ICM) mil- liampere draw is 0.0 mA (with ignition turned O
TESTING battery. b.
HOME ● ● ● 1. 2. 1-20