Check/Reset Energy Cut Oī    •  Turn off the power to the water  ing to the instrucƟ ons in Step 10 of the
          5    (ECO) BuƩ on.                   heater.                             InstallaƟ on secƟ on of this manual.

                                             WARNING! Be sure all covers are       Undersized water heater. If your water
                                             secured to reduce the risk of Į re and   heater runs out of hot water too quick-
                                             electric shock.                       ly, it may be too small for your needs. If
                                                                                   the water heater is old, consider replac-
                                              Insuĸ  cient Hot Water               ing it with a larger model. If the water
                                             or Slow Hot Water                     heater is in good condiƟ on, you may
                                                                                   be able to meet your family’s hot water
                                             Recovery
                                                                                   needs with the exisƟ ng water heater by
                                                WARNING! Because of the increased   installing ThermostaƟ c Mixing Valves at
                                             risk from scalding, if you set the water   each point-of-use and then turning the
                                             heater’s thermostat(s) higher than    thermostat(s) to a higher seƫ  ng. See
        Figure 23 -രEnergy Cut Off (ECO) button
                                             120°F, ThermostaƟ c Mixing Valves     “Step 10” on page 15.
        The Energy Cut Oī  (ECO) shuts oī  pow-  at each point-of-use are parƟ cularly   You can also reduce your home’s hot
        er to the water heater’s elements if the   important (page 4).             water needs by washing clothes in cold
        temperature of the water in the tank   If the hot water is simply not warm   water, installing Ň ow restrictors on
        gets too hot. If the ECO has tripped,   enough, there are several possible   shower heads, repairing leaky faucets,
        you’ll have no hot water. A tripped ECO   causes:                          and taking other conservaƟ on steps.
        can usually be reset, but you should
        have a qualiĮ ed person invesƟ gate the   •  Faulty Thermostatic Mixing Valve in  Reversed connecƟ ons or melted dip
                                               a faucet or shower control (check   tube. Check the hot and cold connec-
        cause of the overheaƟ ng and repair the   other faucets in the house for hot  Ɵ ons and make sure your home’s hot
        problem. Do not turn the power back
                                               water)                              water pipe is connected to the hot wa-
        on unƟ l the cause of the overheaƟ ng
                                             •  One (or both) of the thermostats set  ter outlet on the water heater. Usually,
        has been idenƟ Į ed and repaired.
                                               too low                             reversed connecƟ ons are found soon
        To check the Energy Cut Oī  (ECO)    •  Water heater’s capacity too small  aŌ er the installaƟ on of a new unit. If
        •   Turn off the power to the water heater.  (or usage too high)           copper pipes were soldered while they
          WARNING! Working near an ener-     •  Reversed plumbing connections or   were aƩ ached to the water heater, the
                                               melted dip tube (usually found soon  dip tube may have melted. The dip tube
        gized circuit can result in severe injury   after new installation)
        or death from electrical shock. Check                                      is a long plasƟ c tube inside the tank
                                                                                   aƩ ached to the cold water inlet. If the
        power wires in the electrical juncƟ on   • Plumbing leak                   dip tube has melted, it can be replaced
        box with a non-contact circuit tester to   •  Bad lower heating element (or
                                               lower thermostat)                   by removing the cold water inlet con-
        make sure power is oī .
                                             • Low supply voltage                  necƟ on, removing the old dip tube and
        •   Press the red ECO reset button (see                                    installing a new one.
          photo above).                      ThermostaƟ c Mixing Valves. If the
                                                                                   Plumbing leak. Even a small leak in the
        •  The ECO was tripped if you hear a  hot water is simply not warm enough,   hot water side of the home’s plumbing  TROUBLESHOOTING
          click when it is reset. In most cases,  make sure the faucet you are checking
          a tripped ECO indicates that the   doesn’t have a defecƟ ve ThermostaƟ c   system can make it appear that the wa-
          tank overheated due to a problem   Mixing Valve. Many shower controls    ter heater is producing liƩ le to no hot
          with one of the elements or ther-  now have built-in mixing valves. If   water. Locate and repair the leak.
          mostats—have a qualified person    these devices fail, they can reduce the   Lower heaƟ ng element not working.
          check the upper and lower elements                                       If the lower heaƟ ng element (or, more
          and thermostats and replace if nec-  amount of hot water the shower or   rarely, the lower thermostat) is not
          essary.                            faucet delivers even though there is
                                             plenty of hot water in the tank. Always   working, you will have some hot water
        •  The ECO was not tripped if you    check the water temperature at several   but not as much as before. Because the
          didn’t hear a click. In that case,                                       lower element does most of the work,
          the upper thermostat should be     faucets to make sure the problem is not
          checked by a qualified person.     in a faucet or shower control.        the lower element usually wears out
                                                                                   before the upper element. Replace the
        •  Replace the insulation and the    Thermostats set too low. If the water   lower element and/or thermostat if
          upper access panel.                temperature at several faucets is too   necessary (see page 22).
                                             cool, adjust the thermostat(s) accord-
                                                                   ResidenƟ al Electric Water Heater Use and Care Guide • 19