Page 239 - TORO PRODUCT CATALOGUE NOV_2019
P. 239

 Valve Accessories
 Solenoids
   DCLS-P
• Potted DC latching solenoid for Toro valves used with EZ-Flo Plus, TPV, P150, P220 or P220S
588403
• Solenoid assembly for EZ-Flo Plus, TPV, P150, P220 or P220S
• Captive hex plunger assembly
• 0.5 m leads
SGS-12
• Spike Guard Solenoid compatible with EZ-Flo Plus, TPV, P150, P220 or P220S
• 24 Vac, 50/60 Hz
• Inrush 0.2A
• Holding: 0.1A
• 20,000 volts lightning rating
Valve Wire Sizing Chart – SGS & LWS
LWS
• Low Wattage Solenoid compatible with EZ-Flo Plus, TPV, P150, P220 or P220S
• 24 Vac, 50/60 Hz • Inrush 0.2A
• Holding: 0.1A
EZRegTM Pressure-Regulation Options
EZR-30 and EZR-100
• Pressure-regulator module for use with P150, P220 or P220S
• Precise pressure control with dial design
• EZR-30: 35-200 kPa
• EZR-100: 35-690 kPa
            Maximum One-way Distance (in Meters) Between Controller and Valve using Spike GuardTM or Low Wattage Solenoid*
* 24 VAC Solenoid. Pressure: 1000 kPa. Voltage Drop: 4 V. Minimum Operating Voltage: 20 V. Amperage (peak) 0,12 A.
 Ground Wire
 Control Wire
 1,0 mm2
 1,5 mm2
 2,5 mm2
 4,0 mm2
 1.0 mm2
 600
 750
 900
 1000
 1.5 mm2
 750
 1000
 1200
 1400
 2.5 mm2
 900
 1200
 1500
 1900
 4.0 mm2
 1000
 1400
 1900
 2500
  223
 












































   237   238   239   240   241