Valve Accessories
Solenoids
DCLS-P
• Potted DC latching solenoid for Toro valves used with EZ-Flo Plus, TPV, P150, P220 or P220S
588403
• Solenoid assembly for EZ-Flo Plus, TPV, P150, P220 or P220S
• Captive hex plunger assembly
• 0.5 m leads
SGS-12
• Spike Guard Solenoid compatible with EZ-Flo Plus, TPV, P150, P220 or P220S
• 24 Vac, 50/60 Hz
• Inrush 0.2A
• Holding: 0.1A
• 20,000 volts lightning rating
Valve Wire Sizing Chart – SGS & LWS
LWS
• Low Wattage Solenoid compatible with EZ-Flo Plus, TPV, P150, P220 or P220S
• 24 Vac, 50/60 Hz • Inrush 0.2A
• Holding: 0.1A
EZRegTM Pressure-Regulation Options
EZR-30 and EZR-100
• Pressure-regulator module for use with P150, P220 or P220S
• Precise pressure control with dial design
• EZR-30: 35-200 kPa
• EZR-100: 35-690 kPa
Maximum One-way Distance (in Meters) Between Controller and Valve using Spike GuardTM or Low Wattage Solenoid*
* 24 VAC Solenoid. Pressure: 1000 kPa. Voltage Drop: 4 V. Minimum Operating Voltage: 20 V. Amperage (peak) 0,12 A.
Ground Wire
Control Wire
1,0 mm2
1,5 mm2
2,5 mm2
4,0 mm2
1.0 mm2
600
750
900
1000
1.5 mm2
750
1000
1200
1400
2.5 mm2
900
1200
1500
1900
4.0 mm2
1000
1400
1900
2500
223