DESIGN





       D5 Back of House (Interior)






       D5.7 CO  Detection
               2
       A new Global safety standard has been issued          An  enhanced system is also now  available,
       regarding  CO  detection  which requires an           the Analox Ax60.  This has detector units which
                      2
       upgrade in every restaurant by the end of 2018.       communicate with a central display unit (in the
                                                             office  area)  to  provide  an  alarm  at  the  point
       The UK has had a CO  detection and warning            of  activation,  in  the  office,  and  by  means  of
                              2
       system in place in every restaurant  for  over        a strobe  light located on the rear  wall of the
       15 years.  These are provided by our CO  gas          kitchen.  See ‘System Summaries’ on next page.
                                                    2
       supplier.  The system installed in all restaurants
       opened  before  April 2013 is the  Analox  Ax50.      New restaurants & re-images must utilise an
       This has a combined detector and alarm unit,          enhanced  detection  and warning  system
       with repeater alarms where needed.                    (Analox Ax60 or LogiCO ).  Analox is the UK
                                                                                        2
                                                             preferred supplier as they are a UK manufacturer
       What has changed?                                     with a strong existing business relationship with
       A  revised Global Safety Standard  for  CO       2    Air Products and McDonald’s.
       detection systems has now been finalised.  We
       have worked  closely with the  Global Safety          Existing restaurants  can  continue  to  use  the
       and Equipment  teams and the  main UK  CO        2    existing Ax50 system (with lowered detector
       detection  system (Ax50) will  comply with the        height).
       Global Safety Standard, after one change, ie.
       lowering the detector height to 30 – 45cm from
       floor level.









































        D5.7           CO  Detection                       1.0                        08 October 2014