CONSTRUCT













         Wall Panels

         All laminate panels must be fully balanced to          All laminate wall panels must be fully bonded to
         a  12mm  MDF  core.  The  feature  laminate as         the wall behind plus mechanically fixed.
         specified  on  the  designer’s  drawings  must  be
         on the visible face, however, the balancing            Tight to skirting head level, a full length aluminium
         laminate to the rear of the panel can be               U trim must be installed for the laminate wall
         the contractor’s choice to provide the most            panels to  sit  into.  The  aluminium trim  must  be
         cost  effective  solution.  Laminate  finishes  are    Gooding Aluminium, ref GL PLT 1303 in SAA finish
         documented  in the  design section of this             and  mechanically  fixed  back  to  the  wall  at
         manual.                                                min 600 ctrs. The laminate wall board must be
                                                                rebated  at  the  bottom  rear  edge  to  sit tightly
                                                                into the U trim.
























































          C3.5           Laminate Wall Panels                3.0                        23 June 2016