CONSTRUCT
Wall Panels
All laminate panels must be fully balanced to All laminate wall panels must be fully bonded to
a 12mm MDF core. The feature laminate as the wall behind plus mechanically fixed.
specified on the designer’s drawings must be
on the visible face, however, the balancing Tight to skirting head level, a full length aluminium
laminate to the rear of the panel can be U trim must be installed for the laminate wall
the contractor’s choice to provide the most panels to sit into. The aluminium trim must be
cost effective solution. Laminate finishes are Gooding Aluminium, ref GL PLT 1303 in SAA finish
documented in the design section of this and mechanically fixed back to the wall at
manual. min 600 ctrs. The laminate wall board must be
rebated at the bottom rear edge to sit tightly
into the U trim.
C3.5 Laminate Wall Panels 3.0 23 June 2016