       C3 Shopfitting






       C3.2 Ceramic Tiling

       For all future projects, ceramic tiles are to be laid   There is an associated Ardex guarantee in place
       using X77 and X78 wall and floor tile adhesives,       for their products. Ardex have also offered  to
       manufactured  by Ardex  and supplied by                provide training for any PM’s or site managers,
       Vogue.  The  S16 adhesive with the  E90 admix          in order to ensure the recommended processes
       as previously specified is to be no longer used.       are followed.
       Together  with the change of adhesive, P4
       primer is also specified for use when preparing        Tiling must be set out and installed as indicated
       the existing floor.                                    on  the  designer’s  floor  setting  out  drawing
                                                              including (where applicable)  the feature
       Poor adhesion between the old floor tiles and          curved section.
       the  new  floor  tiles  is  caused  by  the  floor  not
       being degreased. By doing this it allows  the          In the PSP scheme it is critical that the two feature
       adhesive to  achieve  a  stronger  bond.  The  P4      curves are  installed as the  designer’s detail
       primer which has been specified leaves a rough         and that they are separated by the indicated
       surface to the existing floor which allows for a       number of full tiles. Discretion will be given to the
       better bond.                                           contractor for further setting out issues ensuring
                                                              minimal number of cuts and dealing with any
       The specified X77 and X78 adhesives are single         expansion joints that may exist.
       part  resins, and  therefore  require  no  separate
       admix. This is deemed a significant advantage,         All tiles must be laid with 4mm grout  joints
       as it ensures the correct mix, thus improving the      throughout.  Grouting  of the joints between
       bond.                                                  tiles must be complete as soon as the bedding
                                                              has set and hardened sufficiently to allow foot
       The X77 used for wall tiling is not a rapid setting    traffic.  All joints must be solid filled.
       adhesive. Feedback from the tiling contractors
       has been recognised, as the S16 and E90 was            Any  floors  with  deviation  of  levels  or
       reported  to  be setting  too  quickly. Again,  this   considerable cracking of tiles must be discussed
       will allow for a better bond.                          and  additional  specification  agreed  with  the
                                                              McDonald’s PM. Following this discussion, if it is
       Products to be used (Tile on Tile):                    felt that the floor substrate is suitable and excess
       Floors                                                 cracking has been a failure in the tiles then a
       Primer P4, Floor Adhesive Ardex X78, Degreaser         Schluter  DITRA  matting  must  be  installed as
       Ardex DGR, Grout                                       manufacturers detail.
       Walls
       Wall Adhesive Ardex  X77, Degreaser  Ardex             Floors may only be over tiled once. The principal
       DGR, Grout                                             contractor  must  check  early in their  site visits
       (NB: For Tile on Plywood:  Use Primer P51 instead      if  the  existing  floors  have  been  over  tiled  and
       of Primer P4)                                          inform  the  McDonald’s PM and the  designer.
                                                              Where  floors  have  been  previously  over  tiled,
                                                              the tiles must be removed before the new tiles
                                                              installed.




        C3.2           Ceramic Tiling                       2.0                       09 January 2015