Page 427 - B6118-AEW-XX-XX-PP-A-0001_(P15)_Contractors Manual_Neat
P. 427

CONSTRUCT

























                   Common Tiling Scenarios - Floors
                   PLYWOOD FLOORS




                   •  Tiling to timber floors - dry areas
                   •  Internal floors                                            PREMIUM PERF ORMANCE




                       1.  Ensure that the subfloor is made of    2.  Prime the flooring grade Plywood   3.  Fix the tiles to the primed floor using
                       suitable flooring grade plywood and is   using neat ARDEX P51 Primer and allow   ARDEX X7001 Microtec Fibre Reinforced
                       secured in accordance with BS: 8385.  to dry.           Tile Adhesive.












                                                           NEW FLOOR TILES















                                                             PLYWOOD













                                                                        4.  Grout the joints using ARDEX-FLEX FL
                                                                        Flexible Tile Grout.

          C3.2           Ceramic Tiling                       2.0                        09 January 2015