Page 427 - B6118-AEW-XX-XX-PP-A-0001_(P15)_Contractors Manual_Neat
P. 427
CONSTRUCT
Common Tiling Scenarios - Floors
PLYWOOD FLOORS
• Tiling to timber floors - dry areas
• Internal floors PREMIUM PERF ORMANCE
1. Ensure that the subfloor is made of 2. Prime the flooring grade Plywood 3. Fix the tiles to the primed floor using
suitable flooring grade plywood and is using neat ARDEX P51 Primer and allow ARDEX X7001 Microtec Fibre Reinforced
secured in accordance with BS: 8385. to dry. Tile Adhesive.
NEW FLOOR TILES
PLYWOOD
4. Grout the joints using ARDEX-FLEX FL
Flexible Tile Grout.
C3.2 Ceramic Tiling 2.0 09 January 2015