CONSTRUCT

























                   Common Tiling Scenarios - Walls
                   TILE ON TILE




                   •  Tiling to plasterboard - dry areas
                   •  Internal walls                                             PREMIUM PERF ORMANCE






                      1.  Check the existing tiles to ensure they   2.  Thoroughly degrease the tiles and the   3.  Apply ARDEX P4 Primer to the
                      are not loose and fully secured. Infill any   grout joints with ARDEX DEGREASER   cleaned tiles and allow to dry.
                      loose or broken tiles using ARDEX A46   to remove any existing dirt, grease or any
                      External Patch and Repair Mortar.  contaminants, and allow to dry.





                                                            EXISTING TILES










                       4.  Fix the tiles using                                         5.  Grout the joints using
                       ARDEX X77 Microtec Fibre                                        ARDEX-FLEX FL Flexible Tile
                       Reinforced Tile Adhesive.                                       Grout.
























          C3.2           Ceramic Tiling                       2.0                        09 January 2015