        C3 Shopfitting






       C3.3 Floor Movement Joints



       Floor movement joints must be installed in the
       new ceramic floor to reflect existing movement
       joint layouts. New movement joints in drive thru
       buildings should  be DILEX-BWB from  Schluter
       System:

       www.schluter.co.uk/dilex-bwb.aspx


       Specialist  advice to  be sought  for  tiling /
       overtiling adjacent other expansion joints.

       Expansion joints to be laid in full bed of ARDEX
       adhesive as manufacturers product data and
       application  instructions enclosed. Proprietary
       expansion joint cover to be grey to match
       anthracite grout and installed prior to main floor
       tile grouting.