Page 48 - B8773-AEW-XX-XX-PP-A-0001_[P4]_Contractors Manual
P. 48

D R A F T


       2.9.3 ‘Make line’ and Slap Table Monitor Shrouds
       Where the slap table/make line backs onto a           Where  the  slap  table/make  line  doesn’t  back
       wall, the three wall mounted monitors must be         onto a wall, i.e. a sneeze screen, the monitors
       shrouded by black monitor shrouds. Additional         should be pole mounted from the ceiling.
       monitors may also be required - refer to drawings.
       •  The surrounds require installation by the main
          contractor.  The  monitors, brackets, small
          power and data points must be installed in
          the usual manner, concealed by the shroud
       •  Sockets, data points, monitor brackets and
          the  black  shroud  should  be  fitted  by  the
          shopfitter  BEFORE  the  computer  installation
          team arrive
       •  The tiles inside the shroud should be covered
          by BLACK vinyl by the sign contractor.
       •  ALL  sockets  and data points inside the
          shroud should be BLACK
       •  There are also angled front faced shrouds,
          so angled monitors sit confortably
       •  The boxes will have two sets of fixing holes to
          ensure  left  and  right-handed  mounting,  so
          there is no need to order anything bespoke


       Be aware that:
       a)  the  makeline  monitor  should  face  towards
       the counter
       b)  the  monitor  at  the  makeline  -  slap  table
       junction should face away from the makeline
       c) the monitor near the front of the slap table
       should face towards the makeline





















       2.9.3                       ‘Make line’ and Slap Table Monitor Shrouds            3 February 2016