Page 754 - CRESTRON HOME OS-3
P. 754

Configure the Generic Relay-Controlled Device
               Tap the Setup tab to configure the relay controls.
































               Operation Mode:

                    l Momentary: Momentary relays are used to turn a relay on and off for a set duration.
                     Select 1 Momentary Relay to toggle the relay between the on and off state. Select 2
                     Momentary Relays to have one relay enable the on state and the other relay enable the off
                     state.
                    l Digital Input: Digital inputs are used to monitor the device state.

                     Select 1 Digital Input if the device uses one sensor to monitor the on and off state. Select 2
                     Digital Inputs if the device uses two sensors to monitor the on and off state; one sensor to
                     monitor the on state and the other sensor to monitor the off state.
                    l Latching: Latched relays are used to turn a relay on and off and remain in the selected
                     state until an inverse command is sent.
                    l Pulse relay (Seconds): Enter how long the momentary relay should be closed (seconds).
                     The time can be set between 0.1 and 3 seconds. The default is 0.5 seconds.


                     NOTE: The Pulse relay (Seconds) field is not shown when the Operation Mode is set to
                     None or 1 Latched Relay.

               Relay/Digital Input Configuration:












                Product Manual — Doc. 8525Z                                              Crestron Home™ OS • 737
   749   750   751   752   753   754   755   756   757   758   759