Page 25 - UL_Report On_Part 1
P. 25

17 IITGN-UL/Façade  18 IITGN-UL/Façade




 4. Construction  b. Deck slab
         Deck slab at all floor levels is provided with 1mm thick trapezoidal steel decking       Image 4 shows  the placement of
 a. Steel frame  sheet and composite action is achieved by fasteners in form of SDS screws of size   thereinforcement  wires  on  the  deck
 Structural frame consists of Indian standard steel sections for beams and   18×25 mm at a spacing of 300 mm center to center through deck sheet onto the   sheet for achieving composite action.
 columns. ISMB 600 members used for columns whereas ISMB 400 members are   beams. The slab was cast using M-25 (1:1:2) design mix concrete (Figure 9) with OPC
 used as beam sections. Beam column joints are connected with connector plates   to provide a maximum floor thickness of 127 mm. This incorporates an anti-cracking

 through flexible end plate connections. These connections consist of a single   mesh consisting of 8 mm Fe 500 diameter wires at 230 mm center to center.
 plate fillet welded to the end of the beam and site bolted to either a supporting
 column or beam. Image 2 shows the steel structural frame comprising of beams
 and columns. Inset of Image 2 shows flexible end plate connection with three

 bolts fixed to the web of beam sections.












                                                                                                 Image 4: Placement of reinforcement wires
                                                                                                 on the deck sheet


         Figure 9: Cross sectional view of deck slab








 Image 2: Steel structural frame comprising test facility  Image 3: Column base plate fixed with
 pedestal using HSFG M-30 foundation bolts

 For analysis, these connections were considered as simple supports due to the
 absence of continuity of beams across the connections. 8 steel columns are fixed
 to concrete pedestals at base level through High Strength Friction Grip (HSFG)
 M-30  foundation  bolts  with  20mm  thick  column  base  plate.  Each  ISMB  600

 column section is fixed through base plate with 10 foundation bolts.
   20   21   22   23   24   25   26   27   28   29   30