Second floor level had a wooden almirah, a crib and a dining table with 4 chairs. Table 7 provides
fire load at second floor level of compartment 1.
Average Total Calorific Fire
Sr.
No Item Material Qty. unit Weight Weight Value Lo ad
(kg) (kg) (MJ/kg) (MJ)
1 Dining table Wood 1 30 30 17.6 528
2 Cupboard Wood 1 40 40 17.6 704
3 Chairs Wood 7 28 17.6 492.8
Upholstery
(Polypropylene) 4 3 12 35.2 422.4
4 Electric Kettle Polypropylene 1 1 1 48.8 48.4
5 Plates Polypropylene 3 0.3 0.9 48.8 43.56
6 Bowl Polypropyle ne 3 0.3 0.9 48.8 43.56
7 Crib Pine wood 1 90.1 90.1 19.1 1720.91
Shawl/Table
8 Cotton 2 0.25 0.5 15.8 7.9 FLED at first floor level was 177 MJ/m2
cover
1 Curtains (Pair) Polyester 1 2 2 22 44 (10 kg wood equivalent)
Total 4055.53
Table 7: Fire load calculation at second floor level for Test 2