Page 59 - UL_Report On_Part 1
P. 59

49 IITGN-UL/Façade  50 IITGN-UL/Façade















 Second floor level had a wooden almirah, a crib and a dining table with 4 chairs. Table 7 provides
 fire load at second floor level of compartment 1.

 Average   Total   Calorific   Fire
 Sr.

 No       Item  Material    Qty.   unit Weight    Weight      Value     Lo   ad
 (kg)  (kg)  (MJ/kg)  (MJ)

 1    Dining table  Wood     1    30  30  17.6    528
 2  Cupboard  Wood  1  40  40  17.6  704
 3  Chairs  Wood  7  28  17.6  492.8
 Upholstery
 (Polypropylene)  4  3    12  35.2  422.4


 4     Electric Kettle  Polypropylene    1     1    1    48.8  48.4
 5  Plates  Polypropylene     3  0.3  0.9  48.8  43.56

 6  Bowl  Polypropyle  ne  3    0.3  0.9  48.8  43.56
 7     Crib  Pine wood     1       90.1  90.1  19.1  1720.91


 Shawl/Table
 8  Cotton  2  0.25  0.5  15.8  7.9  FLED at first floor level was 177 MJ/m2
 cover
 1  Curtains (Pair)  Polyester  1  2    2  22  44  (10 kg wood equivalent)

 Total  4055.53

 Table 7: Fire load calculation at second floor level for Test 2
   54   55   56   57   58   59   60   61   62   63   64