4 - MODELING AND DESIGN
Powerful structural programs Etabs & Safe, will be used to institute a complete
models of the project and the partial models of any of its component. Excels sheet
will be used to design the elements of the structure as needed.
5 - DESIGN CRITERIA AND LOADS
Design loads are determined according to SBC1101-2018 and the requirements of
the building occupancy, architectural and the electromechanical design.
5.1 - Dead Loads (D)
Dead loads consist of the weight of the structure and all construction elements of a
permanent nature including elevations, cladding, partitions, plaster, tiling, false
ceilings, raised floors, mechanical and electrical fixed equipment’s, roofing, and
mainly fill for landscaping above the various structures, and the contents of
reservoirs measured at full capacity.
- The following basic values are assumed:
Density
Material
Kn/m3
Reinforced concrete 25.00
Block partition walls 20cm 14.40
Block partition walls 15cm 15.50
Block partition walls 10cm 17.50
Backfilling material (sand) 17.00
- The following superimposed loads have been considered according to
the client and architectural design requirements: