5.3 - Flood Loads

                   Flood loads are neglected according location, type and occupancy of the building

                   according to SBC 1101

                   5.4 - Snow Loads


                   Snow loads are not applicable to KSA according to SBC 1101.

                   5.5 - Rain Loads (R)

                                                                                                    2
                   Rain loads shall be permitted to ignore when assigning roof load of 2 KN/M
                   according the provision (3A3.3.2.1 SBC1101)

                   5.6 - Ice Loads

                   Ice loads are not applicable to KSA according to SBC 1101.

                    5.7 - Seismic Loads (E)


                   Building location: Al-Leith city–Kingdom of Saudi Arabia

                   Building Occupancy: Residential Villa/one family

                   Seismic coefficient accordance with (SBC-1101) with the following factors:


                     Risk Category                                                         II
                     Seismic Importance Factor, Ie                                        1.00

                     Soil Profile Description                                          stiff soil

                     Site Classification                                                     D
                     The Mapped MCER acceleration parameter at short
                                                                                         0.150
                     period(Ss)

                     The site coefficients(Fa)                                             1.00
                     The MCER spectral response acceleration parameter
                                                                                           0.150
                     adjusted(SMS)
                     Design earthquake spectral response
                                                                                       0.1013
                     acceleration parameter at short period(SDS)
                     Seismic Design Category                                                 A



                  According to provision (11.1.2-SBC301) the structure is seismic design category A

                   if Ss<=.15g.

                  F= 0.01*W