P. 1352
load
component
Ton/m2
Ceiling + Service
Gypsum board + Mechanical duct allowance 0.05
Covering & floor fill for floor & roof
10 cm finishing 0.20
20 cm finishing (Roof tiling + insulation system
0.320
+ Foam Concrete)
Fibber tanks location 1.00
5.2 - Live Loads (L)
Live loads consist of uniform live loads and, where required.
Uniform live loads are assumed unit loads that are sufficient to provide for
movable and transitory loads, such as the weight of people, furniture, portable
equipment which may be moved over on floors.
Special equipment live loads are based on information provided by the owner and
by the design team, for specific areas if any, and shall be applied according to their
sizes and shape.
Uniform live loads for the various type of occupation are considered as follow:
load
Occupancy or use
Ton/m 2
All Floors (L) 0.20
The load from Antenna if required to be installed on slab should be provided by the
client.