"Oil-Less” Medical Air                                                              Medical Systems


               Appendix A - Desiccant Dryer


               A.6 Dryer Specifications

               Type:                                       Desiccant Heatless

               Design pressure:                            105 PSIG

               Operating pressure:                         60 PSIG minimum, 125 PSIG maximum

               Maximum inlet air temperature:              43ºC (110ºF)

               Ambient temperature:                        4.4ºC (40ºF) minimum, 40.5ºC (105ºF) maximum

               Pressure dew point capability @100 PSIG:      -12ºC (10ºF)

               Normal DP operating range:                  -8ºC (17.6ºF) to -12ºC (10ºF)

               Differential Pressure @ 100 PSIG and
               37.8ºC (100ºF):                             2 to 8 PSIG

               Desiccant:                                  Activated alumina

               Control:                                    Fully automatic solid-state electric fixed cycle (1 minute)

               Power:                                      120 volt 50/60 Hz 1 ph power (100 Watts)







































                                                            A-15