Page 211 - Med Plaza and Cancer Center
P. 211
"Oil-Less” Medical Air Medical Systems
Appendix A - Desiccant Dryer
A.4.1 Maintenance Schedule
20 hp Triplex, 15 hp Quad (Type 2 Dryer) 155 cfm
Service Interval Part number Description Quantity
Every year ELM 22 005 Pre-filter 2
Every year ELM 22 005 After-filter 2
Every year MUF 01 008 Purge muffler 2
Every 5 years DES 01 001 Desiccant 9 bags
Every 5 years VAL 01 013 Check valve 4
Every 5 years GKT 10 008 Tower o-ring 4
Every 5 years GKT 10 007 Canister o-ring 4
As needed VAL 11 003 Switching valve 2
As needed GAG 01 032 Tower pressure gauge 2
Purge valve (Refer to diagram for correct valve)
Every 5 years VAL 04 020 Diaphragm 2
Every 5 years VAL 04 031 Poppet 2
20 hp Quad (Type 2 Dryer) 200 cfm
Service Interval Part number Description Quantity
Every year ELM 22 006 Pre-filter 2
Every year ELM 22 006 After-filter 2
Every year MUF 01 008 Purge muffler 2
Every 5 years DES 01 001 Desiccant 11 bags
Every 5 years VAL 01 013 Check valve 4
Every 5 years GKT 10 008 Tower o-ring 4
Every 5 years GKT 10 007 Canister o-ring 4
As needed VAL 11 003 Switching valve 2
As needed GAG 01 032 Tower pressure gauge 2
Purge valve (Refer to diagram for correct valve)
Every 5 years VAL 04 020 Diaphragm 2
Every 5 years VAL 04 031 Poppet 2
A-12