Page 335 - Womens Pavilion
P. 335

Oil-Less Claw Medical Vacuum


           Appendix B: Variable Speed Drive Inverter


           B.2.2   Parameter List (continued)


                                                                                     Minimum
                                                                                      Setting     Initial   Factory
            Function Parameters              Name                 Setting Range     Increments    Value    Setting
                                 Energization time carrying-over
              ----       563                                    (0 to 65535)             1           0
                                 times
                                 Operating time carrying-over
              ----       564                                    (0 to 65535)             1           0
                                 times
               Multiple   rating  570  Multiple rating setting   0, 1                    1           0




              ----       571     Holding time at a start        0.0 to 10.0s, 9999      0.1s       9999

              ----       573     4mA input check selection      1, 9999                  1         9999
                                 Output interruption detection     0 to 3600s, 9999     0.1s         1s
                         575
                PID control  576  Output interruption detection     0 to 400Hz         0.01Hz       0Hz
                                 time
                                 level
                         577     Output interruption cancel level   900 to 1100%        0.1%       1000%

                                 Auxiliary motor operation
                         578                                    0 to 3                   1           0
                                 selection
                                 Motor connection function
                         579                                    0 to 3                   1           0
                                 selection
                         580     MC switching interlock time    0 to 100s               0.1s         1s

                         581     Start waiting time             0 to 100s               0.1s         1s
                                 Auxiliary motor connection-
                         582                                    0 to 3600s, 9999        0.1s         1s
                                 timedeceleration time
                                 Auxiliary motor disconnection-
                         583                                    0 to 3600s, 9999        0.1s         1s
                                 time acceleration time
                Pump function  584  frequency                   0 to 400Hz             0.01Hz      60Hz
                                 Auxiliary motor 1 starting

                                 Auxiliary motor 2 starting
                         585
                                                                                       0.01Hz
                                                                0 to 400Hz
                                                                                                   60Hz
                                 frequency
                         586     Auxiliary motor 3 starting     0 to 400Hz             0.01Hz      60Hz
                                 frequency
                                 Auxiliary motor 1 stopping
                         587                                    0 to 400Hz             0.01Hz       0Hz
                                 frequency
                                 Auxiliary motor 2 stopping
                         588                                    0 to 400Hz             0.01Hz       0Hz
                                 frequency
                                 Auxiliary motor 3 stopping
                         589                                    0 to 400Hz             0.01Hz       0Hz
                                 frequency
                                 Auxiliary motor start detection
                         590                                    0 to 3600s              0.1s         5s
                                 time
                                 Auxiliary motor stop detection
                         591                                    0 to 3600s              0.1s         5s
                                 time
           4107 9000 95.04                                 B-16