Page 336 - Womens Pavilion
P. 336

Oil-Less Claw Medical Vacuum


            Appendix B: Variable Speed Drive Inverter


            B.2.2   Parameter List (continued)



                                                                                      Minimum
                                                                                       Setting     Initial   Factory
             Function Parameters              Name                 Setting Range     Increments    Value    Setting
                ----      611      Acceleration time at a restart   0 to 3600s, 9999     0.1s       5/15s
                ----      867      AM output fi lter              0 to 5s                 0.01s       0.01s

                ----      869      Current output fi lter         0 to 5s                 0.01s       0.02s
                                   Input phase failure protection
                ----      872                                    0, 1                      1          0
                                   selection                     0, 1, 2                   1          0
                                   Regeneration avoidance
                 Regeneration avoidance function  883  Regeneration avoidance    300 to 800V     0.01Hz     DC380V/
                          882
                                   operation selection
                                                                                         0.1V
                                   operation level
                                                                                                    760V
                                   Regeneration avoidance at
                          884
                                                                 0 to 5
                                                                                           1
                                                                                                      0
                                   deceleration detection sensitivity
                                   Regeneration avoidance
                          885
                                   compensation frequency limit
                                                                  0 to 10Hz, 9999
                                                                                                     6Hz
                                   value
                                   gain
                   parameter  889  Free parameter 2               0 to 9999                1         9999
                          888
                                                                                                     9999
                                                                                           1
                                                                  0 to 9999
                                   Free parameter 1
                Free      886      Regeneration avoidance voltage     0 to 200%          0.1%       100%
                                   Cumulative power monitor digit
                          891                                    0 to 4, 9999              1         9999
                                   shifted times
                          892      Load factor                   30 to 150%              0.1%       100%
                                                                                                    SLD/LD
                                                                                                   value of
                                   Energy saving monitor reference    0.1 to 55kW/ 0 to
                          893                                                         0.01/0.1kW    Applied
                                   (motor capacity)             3600kW                            Capacity
                                                                                                    moter
                 Energy saving monitor  894  Control selection during    0, 1, 2, 3        1         9999
                                   commercial power-supply
                                                                                                      0
                                   operation
                                   Power saving rate reference
                                                                 0, 1, 9999
                                                                                           1
                          895
                                   value
                          896
                                   Power unit cost
                                   Power saving monitor average     0 to 500, 9999       0.01        9999
                          897                                    0, 1 to 1000h, 9999       1         9999
                                   time
                                   Power saving cumulative
                          898                                    0, 1, 10, 9999            1         9999
                                   monitor clear
                                   Operation time rate (estimated
                          899                                     0 to 100%, 9999        0.1%        9999
                                   value)


                                                             B-17                                 4107 9000 95.04
   331   332   333   334   335   336   337   338   339   340   341