Page 57 - UK Standard Products Catalogue 2018_23.10.18
P. 57
Galvanised Steel
Dimensional Information
Planted Root Option
Height (m) BD (mm) TD (mm) PD (mm) DH x DW (mm) Mass (kg) OTM (kNm) Shear (kN) Min. Concrete Dia. (mm)
4 140 140 1000 500 x 100 108 19,43 6,17 1036
5 140 140 1000 500 x 100 124 19,81 5,23 1024
6 140 140 1000 500 x 100 150 20,57 4,79 1041
Flange Plated Option
Height BD TD DH x DW SL x T x BC Anchor Mass OTM Shear Concrete Foundation Size
(m) (mm) (mm) (mm) (mm) Bolts (kg) (kNm) (kN) (mm)
4 140 140 500 x 100 420 x 20 x 300 M24 X 820 115 19,43 6,17 600 sq x 1200 h
5 140 140 500 x 100 420 x 20 x 300 M24 X 820 137 19,81 5,23 600 sq x 1200 h
6 140 140 500 x 100 420 x 20 x 300 M24 X 820 159 20,57 4,79 600 sq x 1200 h
Headload Capacity Information
Height (m) Mounting Arrangement Projection (m) Weight (kg) Extra Light Light Medium Heavy Extra Heavy
Single Arm 0,5 15 2,89 2,51 2,30 2,09 1,65
Double Arm 0,5 15 2,62 2,28 2,08 1,89 1,47
Quadruple Arm 0,5 15 1,53 1,33 1,21 1,11 0,86
4
Single Arm 1,0 15 1,93 1,67 1,52 1,38 1,07
Double Arm 1,0 15 1,72 1,48 1,34 1,20 0,91
Quadruple Arm 1,0 15 1,13 0,97 0,87 0,79 0,59
Single Arm 0,5 15 2,36 2,05 1,86 1,68 1,28
Double Arm 0,5 15 1,95 1,67 1,52 1,37 1,04
Quadruple Arm 0,5 15 1,08 0,93 0,85 0,76 0,57
5
Single Arm 1,0 15 1,62 1,39 1,26 1,13 0,85
Double Arm 1,0 15 1,32 1,12 1,00 0,90 0,64
Quadruple Arm 1,0 15 0,82 0,69 0,62 0,55 0,39
Single Arm 0,5 15 1,92 1,64 1,47 1,31 0,97
Double Arm 0,5 15 1,46 1,24 1,11 0,98 0,71
Quadruple Arm 0,5 15 0,78 0,66 0,59 0,52 0,38
6
Single Arm 1,0 15 1,33 1,12 1,00 0,89 0,64
Double Arm 1,0 15 1,00 0,83 0,73 0,64 0,43
Quadruple Arm 1,0 15 0,59 0,49 0,43 0,37 0,24
Dimensions and technical information given as an indication.
See diagrams beginning on page 308 for info regarding the moments and abbreviations used in above tables.
Valmont reserves the right to make, without delay and without prior notice, the technical or aesthetic modifications that it
deems necessary to improve the products of the Standard Collection.