Page 59 - UK Standard Products Catalogue 2018_23.10.18
P. 59
Galvanised Steel
Dimensional Information
Flange Plated Option
Height BD TD FL DH x DW SL x T x BC Anchor Mass OTM Shear (kN) Concrete Foundation
(m) (mm) (mm) (mm) (mm) (mm) Bolts (kg) (kNm) Size (mm)
4 173 76 1000 500 x 100 260 x 20 x 200 M18/20 x 400 88 5,41 1,41 400 sq x 700 h
5 190 76 1000 500 x 100 260 x 20 x 200 M18/20 x 400 100 7,65 1,69 400 sq x 800 h
6 207 76 1000 500 x 100 400 x 20 x 300 M24 x 820 130 10,13 1,94 500 sq x 900 h
8 241 76 1000 600 x 115 400 x 20 x 300 M24 x 820 200 20,04 3,00 600 sq x 1200 h
10 275 76 1000 600 x 115 400 x 20 x 300 M24 x 820 250 29,16 3,72 700 sq x 1300 h
12 309 76 1000 600 x 115 400 x 20 x 300 M24 x 820 307 37,86 4,29 800 sq x 1500 h
* FL indicates finial length.
Headload Capacity Information
Height (m) Mounting Arrangement Projection (m) Weight (kg) Extra Light Light Medium Heavy Extra Heavy
Single Arm 0,50 15 0,77 0,65 0,59 0,52 0,39
4
Single Arm 1,00 15 0,55 0,46 0,42 0,36 0,26
Single Arm 0,50 15 0,96 0,80 0,73 0,65 0,49
5
Single Arm 1,00 15 0,72 0,60 0,55 0,48 0,35
Single Arm 0,50 15 1,08 0,92 0,83 0,75 0,56
6
Single Arm 1,00 15 0,86 0,72 0,65 0,58 0,42
Single Arm 0,50 15 1,28 1,11 1,00 0,90 0,67
8
Single Arm 1,00 15 1,06 0,91 0,82 0,73 0,53
Single Arm 0,50 15 1,42 1,21 1,10 0,98 0,72
10
Single Arm 1,00 15 1,23 1,04 0,93 0,83 0,60
Single Arm 0,50 15 1,50 1,26 1,11 0,98 0,66
12
Single Arm 1,00 15 1,25 1,10 0,99 0,87 0,62
Dimensions and technical information given as an indication.
See diagrams beginning on page 308 for info regarding the moments and abbreviations used in above tables.
Valmont reserves the right to make, without delay and without prior notice, the technical or aesthetic modifications that it
deems necessary to improve the products of the Standard Collection.