Galvanised Steel


          Headload Capacity Information



                              E. Light   Light   Medium   Heavy   E.Heavy   E.Light   Light   Medium   Heavy   E.Heavy   Design  Shear
          Mast  Mounting  Weight  (24.92m/s)  (26.5m/s)  (27.58m/s)  (28.75m/s)  (31.95m/s)  (24.92m/s)  (26.5m/s)  (27.58m/s)  (28.75m/s)  (31.95m/s)  Moment  Load
           (m)  Arrang.  (kg)
                              TCAT II  TCAT II  TCAT II  TCAT II  TCAT II  TCAT III  TCAT III  TCAT III  TCAT III  TCAT III  (m.daN)  (daN)
           10   Post Top  32  0,686  0,583  0,525   0,470  0,352  0,984  0,836  0,752   0,673  0,506  1583  228
           10  0.5m S-Arm  18  0,531  0,444  0,394  0,348  0,245  0,781  0,657  0,586   0,520  0,380  1563  223
           10  1m S-Arm  18   0,424  0,348  0,305  0,264   0,179  0,642  0,534  0,472   0,415  0,292  1519  219
           10  1.5m S-Arm  16,5  0,336  0,269  0,231  0,195  0,120  0,530  0,433  0,378  0,328  0,220  1485  216
           12   Post Top  20  0,354  0,277  0,233  0,192   0,104  0,567  0,458  0,395   0,336  0,213  1600  223
           12  0.5m S-Arm  18  0,312  0,245  0,204  0,164  0,079  0,500  0,405  0,350   0,298  0,184  1588  222
           12  0.5m S-Arm  12  0,342  0,270  0,227  0,185  0,096  0,540  0,439  0,381   0,328  0,208  1587  220
           12  1m S-Arm  14   0,256  0,194  0,158  0,125   0,047  0,429  0,340  0,291   0,244  0,145  1582  222
           12  1m S-Arm  10   0,277  0,211  0,175  0,140   0,059  0,456  0,365  0,312   0,263  0,162  1579  220
           12  1.5m S-Arm  12  0,199  0,141  0,109  0,080   --    0,356  0,276  0,230   0,187  0,097  1579  222
           12  1.5m S-Arm  10  0,208  0,151  0,118  0,086   --    0,370  0,287  0,241   0,197  0,105  1577  221















          Foundation Information


          Concrete Foundation In Accordance with BS EN 12767:2007. N.A. 7,  In Good, Medium & Poor Ground. See Note Below.

                                                    Good                  Medium                   Poor
           Mast (m)  Weight (kg)  Mounting Arrangement
                                                G=630 kN/m2 per m.     G=390 kN/m2 per m.     G=230 kN/m2 per m.
             10      32         Post Top       �0.5m x 1.5m P/Depth   �0.75m x 1.5m P/Depth  �1.25m x 1.5m P/Depth
             10      18       0.5m Single Arm  �0.5m x 1.5m P/Depth   �0.75m x 1.5m P/Depth  �1.25m x 1.5m P/Depth
             10      18       1m Single Arm    �0.5m x 1.5m P/Depth   �0.75m x 1.5m P/Depth  �1.25m x 1.5m P/Depth
             10      16,5      1.5m S-Arm      �0.5m x 1.5m P/Depth   �0.75m x 1.5m P/Depth  �1.25m x 1.5m P/Depth
             12      20         Post Top       �0.5m x 1.5m P/Depth   �0.75m x 1.5m P/Depth  �1.25m x 1.5m P/Depth
             12      18        0.5m S-Arm      �0.5m x 1.5m P/Depth   �0.75m x 1.5m P/Depth  �1.25m x 1.5m P/Depth
             12      12        0.5m S-Arm      �0.5m x 1.5m P/Depth   �0.75m x 1.5m P/Depth  �1.25m x 1.5m P/Depth
             12      14        1m S-Arm        �0.5m x 1.5m P/Depth   �0.75m x 1.5m P/Depth  �1.25m x 1.5m P/Depth
             12      10        1m S-Arm        �0.5m x 1.5m P/Depth   �0.75m x 1.5m P/Depth  �1.25m x 1.5m P/Depth
             12      12        1.5m S-Arm      �0.5m x 1.5m P/Depth   �0.75m x 1.5m P/Depth  �1.25m x 1.5m P/Depth
             12      10        1.5m S-Arm      �0.5m x 1.5m P/Depth   �0.75m x 1.5m P/Depth  �1.25m x 1.5m P/Depth
          Note: Good, Medium & Poor ground descriptions can be found in BD94/07 & PD6547:2004+A1:2009. Foundation size is designed in accordance with BS
          EN 12767:2007. N.A 7. Concrete to be plain C25/30 air entrained concrete for frost resistance. Any water present in holes to be removed prior to placing
          concrete. Column to be located centrally within the foundation.










          Dimensions and technical information given as an indication.
          See diagrams beginning on page 308 for info regarding the moments and abbreviations used in above tables.
          Valmont reserves the right to make, without delay and without prior notice, the technical or aesthetic modifications that it
          deems necessary to improve the products of the Standard Collection.
   58   59   60   61   62   63   64   65   66   67   68