Galvanised Steel
Dimensional Information
Planted Root Option
Height (m) BD (mm) TD (mm) PD (mm) DH x DW (mm) Mass (kg) OTM (kNm) Shear (kN) Min. Concrete Dia. (mm)
6 220 101 1000 600 x 115 121 23,45 4,58 1187
8 257,4 101 1200 600 x 115 173 36,90 5,94 1070
10 296,5 101 1500 600 x 115 237 51,15 7,16 759
Flange Plated Option
Height BD TD DH x DW SL x T x BC Anchor Mass OTM Shear Concrete Foundation Size
(m) (mm) (mm) (mm) (mm) Bolts (kg) (kNm) (kN) (mm)
6 203 101 600 x 115 420 x 25 x 300 M24 x 820 128 23,45 4,58 700 sq x 1200 h
8 237 101 600 x 115 420 x 25 x 300 M24 x 820 172 36,90 5,94 800 sq x 1500 h
10 271 101 600 x 115 420 x 25 x 300 M24 x 820 220 51,15 7,16 900 sq x 1700 h
12 305 101 600 x 115 420 x 25 x 300 M24 x 820 277 66,41 7,81 1000 sq x 1900 h
Headload Capacity Information
Height (m) Mounting Arrangement Projection (m) Weight (kg) Extra Light Light Medium Heavy Extra Heavy
Post Top N/A 50 3,00 2,46 2,14 1,85 1,19
6
Single Arm 0.5m 15 2,07 1,69 1,48 1,26 0,82
Post Top N/A 50 2,79 2,36 2,08 1,85 1,30
8
Single Arm 1.0m 15 1,87 1,56 1,38 1,23 0,83
Post Top N/A 50 3,04 2,59 2,34 2,08 1,50
10
Single Arm 1.0m 15 2,12 1,87 1,73 1,56 1,13
Post Top N/A 50 3,18 2,71 2,46 2,18 1,60
12
Single Arm 1.0m 15 2,01 1,77 1,64 1,50 1,21
Note: A banner with dimensions of 2m high x 0.5m has been allowed for within the pole calculation in addition to the figures quoted above.
Dimensions and technical information given as an indication.
See diagrams beginning on page 308 for info regarding the moments and abbreviations used in above tables.
Valmont reserves the right to make, without delay and without prior notice, the technical or aesthetic modifications that it
deems necessary to improve the products of the Standard Collection.