MEANS OF EGRESS



              4. Group R-3 and R-4 occupancies shall be permitted  vidual building stories, shall be separated in accordance with
                to have one exit or access to a single exit.  the provisions of this section.
              5. Individual single-story or multistory dwelling units  [BE] 1007.1.1 Two exits or exit access doorways. Where
                shall be permitted to have a single exit or access to a  two exits, exit access doorways, exit access stairways or
                single exit from the dwelling unit provided that both  ramps, or any combination thereof, are required from any
                of the following criteria are met:
                                                                 portion of the exit access, they shall be placed a distance
                    5.1. The  dwelling unit  complies with Section  apart equal to not less than one-half of the length of the
                        1006.2.1 as a  space with one means of   maximum overall diagonal dimension of the building or
                        egress.
                                                                 area to be served measured in a straight line between them.
                    5.2. Either the exit from the dwelling unit dis-  Interlocking or scissor stairways shall be counted as one
                        charges directly to the exterior at the level  exit stairway.
                        of exit discharge, or the exit access outside
                        the dwelling unit’s entrance door provides  Exceptions:
                        access to not less than two approved inde-   1. Where interior exit stairways or ramps are inter-
                        pendent exits.                                  connected by a 1-hour fire-resistance-rated corri-
              [BE] 1006.3.3.1 Mixed occupancies. Where one exit,        dor conforming to the requirements of  Section
              or  exit  access stairway or  ramp providing access to    1020, the required exit separation shall be mea-
              exits at other stories, is permitted to serve individual  sured along the shortest direct line of  travel
              stories,  mixed occupancies shall  be permitted  to be    within the corridor.
              served by single  exits provided  that each individual
              occupancy complies  with the applicable requirements   2. Where a building is equipped throughout with an
              of Table 1006.3.3(1) or 1006.3.3(2) for that occupancy.   automatic sprinkler system in accordance with
              Where applicable,  cumulative  occupant loads from        Section 903.3.1.1 or 903.3.1.2, the separation dis-
              adjacent occupancies shall be considered to be in accor-  tance shall be not less than one-third of the length
              dance with the provisions of Section 1004.1. In each      of the maximum overall diagonal dimension  of
              story of a mixed occupancy building,  the  maximum        the area served.
              number of occupants served by  a single  exit shall  be  [BE] 1007.1.1.1 Measurement point. The separation
              such that the sum of the ratios of the calculated number  distance required in Section 1007.1.1 shall be measured
              of occupants  of  the space  divided by the  allowable  in accordance with the following:
              number of occupants indicated in Table 1006.3.3(2) for
              each occupancy does not exceed one. Where dwelling     1. The separation distance  to  exit or  exit  access
              units are located on a story with other occupancies, the  doorways shall be measured to any point along
              actual number of dwelling units divided  by four plus     the width of the doorway.
              the ratio from the other occupancy does not exceed one.
                                                                     2. The separation distance to exit access stairways
                                                                        shall be measured to the closest riser.
                           SECTION 1007
                      EXIT AND EXIT ACCESS                           3. The separation distance to exit access ramps shall
                    DOORWAY CONFIGURATION                               be measured to the start of the ramp run.
                                                                 [BE] 1007.1.2 Three or more exits or exit access door-
         [BE] 1007.1 General. Exits, exit access doorways, and exit
         access stairways and ramps serving spaces, including indi-  ways. Where access to three or more exits is required, not
                                                   [BE] TABLE 1006.3.3(2)
                             STORIES WITH ONE EXIT OR ACCESS TO ONE EXIT FOR OTHER OCCUPANCIES
                                                                                          MAXIMUM COMMON PATH OF
                                                                      MAXIMUM OCCUPANT
                      STORY                      OCCUPANCY                                EGRESS TRAVEL DISTANCE
                                                                       LOAD PER STORY
                                                                                                  (feet)
                                                  b
                                                      b
                                               A, B , E F , M, U            49                     75
                                                  H-2, H-3                   3                     25
         First story above or below grade plane
                                             H-4, H-5, I, R-1, R-2 a, c     10                     75
                                                    S b, d                  29                     75
         Second story above grade plane          B, F, M, S d               29                     75
         Third story above grade plane and higher   NP                      NA                     NA
         For SI: 1 foot = 304.8 mm.
         NP = Not Permitted.
         NA = Not Applicable.
         a. Buildings classified as Group R-2 equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2 and provided
           with emergency escape and rescue openings in accordance with Section 1030.
         b. Group B, F and S occupancies in buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 shall have a
           maximum exit access travel distance of 100 feet.
         c. This table is used for R-2 occupancies consisting of sleeping units. For R-2 occupancies consisting of dwelling units, use Table 1006.3.3(1).
         d. The length of exit access travel distance in a Group S-2 open parking garage shall be not more than 100 feet.

         156                                                                        2018 INTERNATIONAL FIRE CODE ®
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.