             [BE] 1029.8 Common path of egress travel. The common      5. Thirty-six inches  (914 mm) for level or  ramped
             path of egress travel shall not exceed 30 feet (9144 mm) from  aisles having seating on only one side.
             any seat to a point where an occupant has a choice of two      Exception: Thirty inches (762 mm) where  the
             paths of egress travel to two exits.                           aisle serves fewer than 15  seats and  does not
               Exceptions:                                                  serve as part of an accessible route.
                  1. For areas serving less than 50 occupants, the com-  [BE] 1029.9.2 Aisle catchment area. The aisle shall pro-
                    mon path of egress travel shall not exceed 75 feet  vide sufficient capacity for the number of persons accom-
                    (22 860 mm).                                     modated by the catchment area served by the aisle. The
                                                                     catchment area served by an aisle is that portion of the
                  2. For smoke-protected or open-air assembly seating,
                    the common path of egress travel shall not exceed  total space served by that section of the aisle. In establish-
                    50 feet (15 240 mm).                             ing catchment areas, the assumption shall be made  that
                                                                     there is a balanced use of all  means of egress, with the
               [BE] 1029.8.1 Path through adjacent row. Where one of  number of persons in proportion to egress capacity.
               the two paths of travel is across the aisle through a row of
               seats to another aisle, there shall be not more than 24 seats  [BE] 1029.9.3 Converging aisles. Where aisles converge
               between the two  aisles, and  the  minimum clear width  to form a single path of egress travel, the required capacity
               between rows for the row between the two aisles shall be  of that path shall be not less than the combined required
               12 inches (305  mm)  plus 0.6 inch (15.2 mm) for each  capacity of the converging aisles.
               additional seat above seven in the row between aisles.  [BE] 1029.9.4 Uniform width and capacity. Those por-
                                                                     tions of aisles, where egress is possible in either of two
                  Exception: For smoke-protected or open-air assembly
                  seating there shall be not more than 40 seats between  directions, shall be uniform in minimum width or required
                  the two aisles and the minimum clear width shall be 12  capacity.
                  inches (305 mm) plus 0.3 inch (7.6 mm) for each addi-  [BE] 1029.9.5 Dead-end aisles. Each end of an aisle shall
                  tional seat.                                       be continuous to a cross aisle, foyer, doorway, vomitory,
                                                                     concourse or  stairway in accordance with Section
             [BE] 1029.9 Assembly aisles are required. Every occupied
             portion of any building, room or space used for assembly pur-  1029.9.7 having access to an exit.
             poses that contains seats, tables, displays, similar fixtures or  Exceptions:
             equipment shall be provided with aisles leading to exits or  1. Dead-end aisles shall be not greater than 20 feet
             exit access doorways in accordance with this section.          (6096 mm) in length.
               [BE] 1029.9.1 Minimum aisle width. The minimum clear      2. Dead-end aisles longer than 16 rows are permit-
               width for aisles shall comply with one of the following:     ted where seats beyond the 16th row dead-end
                  1. Forty-eight inches (1219 mm)  for  stepped  aisles     aisle are not more than 24  seats  from  another
                    having seating on both sides.                           aisle, measured along  a row  of seats having a
                                                                            minimum clear width of 12 inches (305 mm) plus
                       Exception: Thirty-six inches (914 mm) where
                       the stepped aisles serve less than 50 seats.         0.6 inch (15.2 mm) for each additional seat above
                                                                            seven in the row where seats have backrests or
                  2. Thirty-six inches (914 mm) for stepped aisles hav-     beyond 10 where seats are without backrests in
                    ing seating on only one side.
                                                                            the row.
                       Exception:  Twenty-three inches (584  mm)         3. For smoke-protected or open-air assembly seat-
                       between  a stepped aisle  handrail and seating       ing, the  dead-end aisle length  of vertical  aisles
                       where a stepped aisle does not serve more than       shall not exceed a distance of 21 rows.
                       five rows on one side.
                                                                         4. For smoke-protected or open-air assembly seat-
                  3. Twenty-three inches (584 mm) between a stepped         ing, a longer dead-end  aisle is permitted where
                    aisle  handrail or  guard and  seating where  the       seats beyond the 21-row dead-end aisle are not
                    stepped aisle is subdivided by a mid-aisle handrail.
                                                                            more than 40 seats from another aisle, measured
                  4. Forty-two inches (1067 mm) for level or ramped         along a row of seats having an aisle accessway
                    aisles having seating on both sides.                    with a minimum clear width of 12 inches (305
                       Exceptions:                                          mm) plus 0.3 inch (7.6 mm) for each additional
                                                                            seat above seven in the row where seats have
                         1. Thirty-six inches (914 mm) where the aisle
                           serves less than 50 seats.                       backrests or beyond 10 where seats are without
                                                                            backrests in the row.
                         2. Thirty inches (762  mm) where the  aisle
                           serves  fewer than 15  seats and does  not
                           serve as part of an accessible route.








             2018 INTERNATIONAL FIRE CODE ®                                                                      191
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.