Page 227 - 2018_IFC
P. 227

MEANS OF EGRESS



              [BE]  1029.14.1.3 Edge protection. Ramped  aisles    tion of each tread is readily apparent when viewed in
              shall have edge protection in accordance with Sections  descent. Such stripe shall be not less than 1 inch (25
              1012.10 and 1012.10.1.                               mm), and not more than 2 inches (51 mm), wide.
                Exception: In assembly spaces with fixed seating,    Exception:  The contrasting marking stripe is per-
                edge protection is not  required on the sides of     mitted to be omitted where tread surfaces are such
                ramped  aisles where the ramped  aisles provide      that the location of each  tread is readily apparent
                access to the adjacent seating and aisle accessways.  when viewed in descent.
           [BE] 1029.14.2 Stepped aisles.  Aisles with a  slope    [BE] 1029.14.2.4 Nosing and profile. Nosing and riser
           exceeding one unit vertical in eight units horizontal (12.5-  profile shall comply with Sections 1011.5.5 through
           percent slope) shall consist of a series of risers and treads  1011.5.5.3.
           that extends across the full width of aisles and complies  [BE] 1029.15 Seat stability.  In a  building, room  or space
           with Sections 1029.14.2.1 through 1029.14.2.4.     used for assembly purposes, the seats shall be securely fas-
              [BE] 1029.14.2.1 Treads.  Tread depths shall be not  tened to the floor.
              less than 11 inches (279 mm) and shall have dimen-  Exceptions:
              sional uniformity.
                                                                   1. In a building, room or space used for assembly pur-
                Exception:  The tolerance between adjacent treads    poses or portions thereof without ramped or tiered
                              3
                shall not exceed  /  inch (4.8 mm).                  floors for seating and with 200 or fewer seats, the
                               16
              [BE] 1029.14.2.2  Risers.  Where the gradient of       seats shall not be required to be fastened to the floor.
              stepped  aisles is to be the same as the gradient of  2.  In a building, room or space used for assembly pur-
              adjoining seating areas, the riser height shall be not less  poses or portions thereof with seating at tables and
              than 4 inches (102 mm) nor more than 8 inches (203     without ramped or tiered floors for seating, the seats
              mm) and shall be uniform within each flight.           shall not be required to be fastened to the floor.
                Exceptions:                                        3.  In a building, room or space used for assembly pur-
                   1. Riser height nonuniformity shall be limited to  poses or portions thereof without  ramped or tiered
                     the extent necessitated by changes in the gra-  floors for seating and with greater than 200 seats, the
                     dient of the adjoining seating area to maintain  seats shall be fastened together in groups of not less
                     adequate sightlines. Where nonuniformities      than three or the seats shall be securely fastened to
                           3
                     exceed  /  inch (4.8 mm)  between adjacent      the floor.
                             16
                     risers, the exact location of such nonuniformi-  4. In a building, room or space used for assembly pur-
                     ties shall be indicated with a distinctive mark-  poses where flexibility of the seating arrangement is
                     ing stripe on each tread  at the  nosing or     an  integral part of the design  and function  of  the
                     leading  edge adjacent to the nonuniform ris-   space and seating is on tiered levels, not more than
                     ers. Such stripe shall be not less than 1 inch  200 seats shall not be required to be fastened to the
                     (25 mm), and not more than 2 inches (51 mm),    floor. Plans showing seating, tiers and aisles shall be
                     wide. The edge marking stripe shall be distinc-  submitted for approval.
                     tively different from the contrasting marking
                     stripe.                                       5. Groups of  seats within a building, room or space
                                                                     used for assembly purposes separated from other
                   2. Riser heights not exceeding 9 inches (229      seating by  railings,  guards, partial  height walls  or
                     mm) shall be permitted where they are neces-    similar  barriers  with  level floors and having not
                     sitated by the slope of the adjacent seating    more than 14 seats per group shall not be required to
                     areas to maintain sightlines.                   be fastened to the floor.
                [BE]  1029.14.2.2.1 Construction tolerances. The   6. Seats intended for  musicians or other performers
                tolerance between adjacent risers on a stepped aisle  and separated by railings,  guards, partial height
                that were  designed  to be equal height  shall not   walls or similar barriers shall not be required to be
                      3
                exceed  /  inch (4.8 mm). Where the stepped aisle is  fastened to the floor.
                       16
                designed in accordance with Exception 1 of Section
                1029.14.2.2, the stepped aisle  shall be constructed  [BE] 1029.16 Handrails. Ramped  aisles having a slope
                so that each riser of unequal height, determined in  exceeding one unit vertical in 15 units horizontal (6.7-percent
                                                    3
                the  direction of descent, is not  more than  /  inch  slope) and stepped aisles shall be provided with handrails in
                                                     8
                (9.5 mm) in height different from adjacent risers  compliance with Section 1014 located either at one or both
                where stepped aisle treads are less than 22 inches  sides of the aisle or within the aisle width.
                                    3
                (560 mm) in depth and  /  inch (19.1 mm) in height  Exceptions:
                                     4
                different from adjacent risers where stepped  aisle  1. Handrails are not required for  ramped  aisles with
                treads are 22 inches (560 mm) or greater in depth.   seating on both sides.
              [BE] 1029.14.2.3 Tread contrasting marking stripe.   2. Handrails are not required where, at the side of the
              A contrasting marking stripe shall be provided on each  aisle, there is a guard with a top surface that com-
              tread at the nosing or leading edge such that the loca-


         194                                                                        2018 INTERNATIONAL FIRE CODE ®
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.
   222   223   224   225   226   227   228   229   230   231   232