Page 240 - 2018_IFC
P. 240

CONSTRUCTION REQUIREMENTS FOR EXISTING BUILDINGS



               5. Group I.                                        provide a clear opening width of 28 inches (711 mm). The
                                                                  minimum clear opening height of doorways shall be 80
               6. Group M.
                                                                  inches (2032 mm).
                    Exception:  Buildings less than 3,000 square feet  Exceptions:
                          2
                    (279 m )  in  gross sales area on one  story  only,
                    excluding mezzanines.                               1. The minimum and maximum width shall not apply
                                                                           to door openings that are not part of the required
               7. Group R-1.                                               means of egress in occupancies in Group R-2 and
                                                                           R-3 units that are not required to be an Accessible
                    Exception: Where each  sleeping unit has  direct
                                                                           Type A unit or Type B unit.
                    access to the outside of the building at grade.
                                                                        2. Door  openings  to storage closets  less than 10
               8. Group R-2.                                               square feet (0.93 m ) in area shall not be limited by
                                                                                          2
                    Exception: Where each  dwelling unit or  sleeping      the minimum clear opening width.
                    unit has direct access to the outside of the building at  3. The width of door leaves in revolving doors that
                    grade.                                                 comply with Section 1010.1.4.1 shall not be lim-
                                                                           ited.
               1104.5.1 Emergency power duration and installation.
               Emergency power for means of egress illumination shall   4. The  maximum width of door leaves in power-
               be provided in  accordance with Section  1203.  In  other   operated doors  that  comply with Section
               than Group I-2, emergency power shall be provided for       1010.1.4.2 shall not be limited.
               not less than 60 minutes for systems requiring emergency  5. Door openings within a dwelling unit shall have a
               power.                                                      minimum clear opening height of 78 inches (1981
                                                                           mm).
             1104.6 Guards. Guards complying with this section shall be
             provided at the open sides of means of egress that are more  6. In dwelling and sleeping units that are not required
             than 30 inches (762 mm) above the floor or grade below.       to  be Accessible  units, Type A  units or Type B
                                                                           units, exterior  door openings, other than  the
               1104.6.1 Height of guards. Guards shall form a protective   required  exit door, shall  have a minimum clear
               barrier not less than 42 inches (1067 mm) high.             opening height of 76 inches (1930 mm).
                  Exceptions:                                           7. Exit access doors serving a room not larger than 70
                                                                                          2
                                                                           square feet (6.5  m ) shall have a minimum  door
                    1. Existing guards on the open side of exit access
                                                                           leaf width of 24 inches (610 mm).
                       and exit  stairways and  ramps shall be not  less
                       than 30 inches (760 mm) high.                    8. The minimum clear opening width shall not apply
                                                                           to doors for nonaccessible showers or sauna com-
                    2. Existing guards within dwelling units shall be not  partments.
                       less than 36 inches (910 mm) high.
                                                                        9. The minimum clear opening width shall not apply
                    3. Existing guards in assembly seating areas.          to the doors for nonaccessible toilet stalls.
               1104.6.2 Opening limitations.  Open  guards shall have  10. Door closers and door stops shall be permitted to
               balusters or ornamental patterns such that a 6-inch-diame-  be 78 inches (1980 mm) minimum above the floor.
               ter (152 mm) sphere cannot pass through any opening up  1104.7.1 Group I-2. In Group I-2 occupancies, means of
               to a height of 34 inches (864 mm).                    egress doors where used for the movement of beds shall
                                                                                                            1
                                                                     provide  a minimum  clear opening  width of 41 /  inches
                  Exceptions:                                                                                2
                                                                     (1054 mm).
                    1. At elevated walking surfaces for access  to, and  Doors serving as means of egress doors and not used
                       use  of, electrical, mechanical or plumbing sys-  for  movement of beds shall provide a minimum  clear
                       tems or equipment, guards shall have balusters or  opening width of 32 inches (813 mm).
                       be  of solid  materials such that a  sphere with  a  1104.7.2 Ambulatory care. In ambulatory care facilities,
                       diameter  of 21 inches (533 mm)  cannot pass  doors serving as means of egress from patient treatment
                       through any opening.
                                                                     rooms shall provide a minimum clear opening width of 32
                    2. In occupancies in Group I-3, F, H or S, the clear  inches (813 mm).
                       distance between intermediate rails measured at  1104.8 Opening force for doors. The opening force for inte-
                       right angles to the rails shall not exceed 21 inches  rior side-swinging doors without closers shall not exceed a 5-
                       (533 mm).                                  pound (22 N) force. The opening forces do not apply to the
                                                                  force required to retract latch bolts or disengage other devices
                    3. Approved existing open guards.
                                                                  that hold the door in a closed position. For other side-swing-
             1104.7 Size of doors.  The required capacity of each door  ing, sliding and folding doors, the door latch shall release
             opening shall be sufficient for the occupant load thereof and  when subjected to a force of not more than 15 pounds (66 N).
             shall provide a minimum clear opening width of 28 inches  The door shall be set in motion when subjected to a force not
             (711 mm). Where this section  requires  a minimum clear  exceeding 30 pounds (133 N). The door shall swing to a full-
             opening width of 28 inches (711 mm) and a door opening  open position when subjected to a force of not more than 50
             includes two door leaves without a mullion, one leaf shall  pounds (222 N). Forces shall be applied to the latch side.

             2018 INTERNATIONAL FIRE CODE ®                                                                      207
  Copyrighted © 2017 by, or licensed to, ICC (ALL RIGHTS RESERVED); licensed to UL, LLC pursuant to License Agreement with ICC. No further reproductions authorized or distribution authorized.
  ANY UNAUTHROIZED REPRODUCTION OR DISTRIBUTION IS A VIOLATION OF THE FEDERAL COPYRIGHT ACT AND THE LICENSE AGREEMENT; AND SUBJECT TO CIVIL AND CRIMINAL PENALTIES THEREUNDER.