Page 171 - ICC IEBC 2018
P. 171

APPENDIX C



                                                    [BS] TABLE C202.1.2
                               SUPPLEMENT FASTENERS AT PANEL EDGES AND INTERMEDIATE FRAMING
                                                                 MAXIMUM SUPPLEMENTAL
                                                  MAXIMUM
                             EXISTING FASTENER   SUPPLEMENTAL     FASTENER SPACING FOR   EDGE ZONE FOR V ult  > 160 MPH
                                                                                                 d
                                                                          c
                             SPACING (EDGE OR                  INTERIOR ZONE  LOCATIONS FOR
           EXISTING FASTENERS                 FASTENER SPACING                            AND EXPOSURE C, OR V ult  >
                               INTERMEDIATE   FOR 130 MPH < V ult  ≤   MPH V ult  > 140 MPH AND EDGE   180 MPH AND EXPOSURE B
                                SUPPORTS)                       ZONES NOT COVERED BY THE
                                                  140 MPH
                                                                  COLUMN TO THE RIGHT
                                                                                        4″ o.c.  at panel edges and
                                                                                            b
         Staples or 6d             Any            6″ o.c. b             6″ o.c. b
                                                                                            b
                                                                                        4″ o.c.  at intermediate supports
         8d clipped head or round                             None necessary along edges of   4″ o.c.  at panel edges and
                                                                                            a
                                                                           b
                                                                                            a
           head smooth shank   6″ o.c. or less  None necessary  panels but 6″ o.c.  at intermediate   4″ o.c.  at intermediate supports
                                                              supports of panel
         8d clipped head or round                                                       4″ o.c.  at panel edges and
                                                                                            a
                                                                                            a
           head ring shank     6″ o.c. or less  None necessary       None necessary     4″ o.c.  at intermediate supports
                                                              6″ o.c.  along panel edges and
                                                                   a
         8d clipped head or round                      a           b                    4″ o.c.  at panel edges and
                                                                                            a
                                                                                            a
           head smooth shank  Greater than 6″ o.c.  6″ o.c.    6″ o.c.  at intermediate supports   4″ o.c.  at intermediate supports
                                                              of panel
         8d clipped head or round                      a                     a          4″ o.c.  at panel edges and
                                                                                            a
                                                                                            a
           head ring shank   Greater than 6″ o.c.  6″ o.c.              6″ o.c.         4″ o.c.  at intermediate supports
         For SI: 1 inch = 25.4 mm; 1 foot = 304.8 mm; 1 mile per hour = 0.447 m/s.
         a. Maximum spacing determined based on existing fasteners and supplemental fasteners.
         b. Maximum spacing determined based on supplemental fasteners only.
         c. Interior zone = sheathing that is not located within 4 feet of the perimeter edge of the roof or within 4 feet of each side of a ridge.
         d. Edge zone = sheathing that is located within 4 feet of the perimeter edge of the roof and within 4 feet of each side of a ridge.








































         152                                                            2018 INTERNATIONAL EXISTING BUILDING CODE  ®