Page 11 - 好惠-断路器
P. 11

AKBO-63 Residual Current Breaker Overlload



                                          Applications
                                          Construction and feature
                                          ■  Provides protection against earth fault/leakage current, short-circuit and overload;
                                          ■  High short-circuit capacity;
                                          ■  Provides complementary protection against direct contact by human body;
                                          ■  Effectively protects electric equipment against insulating failure;
                                          ■  Contact position indication;
                                          ■  Provides protection against over-voltage;
                                          ■  Provides comprehensive protection to household and commercial distribution systems.
                                          Technical data
                                          ■  Type:electronic type;
                                          ■  Residual current characteristics:AC;
                                          ■  Tripping curve:B,C;
                                          ■  Rated short-circuit capacity:6000A;
                                          ■  Rated current(A):1,2,4,6,10,16,20,25,32;
                                          ■  Rated voltage:240V AC;
                                          ■  Rated frequency:50/60Hz;
                                          ■  Rated residual operating current(A):10,30,100;
                                          ■  Tripping duration:Instantaneous ≤0.1s;
                                          ■  Electro mechanical endurance:4000 cycles;
                                          ■  Connedtion terminal:pilar terminal with clamp;
                                          ■  Connection capacity;
                                                              2
                                          ■  Flexible conductor 10mm ;
                                          ■  Rigid conductor 16mm ; 2
                                          ■  Installation;
                                          ■  Onsymmetrical DIN rall 35mm;
                                          ■  Panel mounting.



                                           Overall and installation dimension










































                                                                                             www.yuanky.com     7      Residual Current Breaker Overload
   6   7   8   9   10   11   12   13   14   15   16