Page 23 - PD 1096 BASIC LAW
P. 23

The National Building Code (P.D. 1096)



                                                       CHAPTER 9


                                                      SANITATION


                       SECTION 901.  General Requirements

                       Subject  to  the  provisions  of  Book  II  of  the  Civil  Code  of  the  Philippines  on  Property,
               Ownership,  and  its  Modification,  all  buildings  hereafter  erected,  altered,  remodeled,  relocated  or
               repaired for human habitation shall be provided with adequate and potable water supply, plumbing
               installation, and suitable  wastewater treatment or disposal system, storm water drainage, pest  and
               vermin  control,  noise  abatement  device,  and  such  other  measures  required  for  the  protection  and
               promotion of health of persons occupying the premises and others living nearby.


                       SECTION 902.  Water Supply System

                       (a)  Whenever  available,  the  potable  water  requirements  for  a  building  used  for  human
               habitation shall be supplied from existing municipal or city waterworks system.
                       (b)  The  quality  of  drinking  water  from  meteoric,  surface  or  underground  sources  shall
               conform to the criteria set in the latest approved National Standards for Drinking Water.
                       (c)  The design, construction and operation of deepwells for the abstraction of groundwater
               shall be subject to the provisions of the Water Code of the Philippines.
                       (d)  The  design,  construction  and  operation  of  independent  waterworks  systems  private
               housing  subdivisions  or  industrial  estates  shall  be  governed  by  existing  laws  relating  to  local
               waterworks system.
                       (e)  The  water  piping  installations  inside  buildings  and  premises  shall  conform  to  the
               provisions of the National Plumbing Code of the Philippines.


                       SECTION 903.  Wastewater Disposal System

                       (a)  Sanitary sewage from buildings and neutralized or pre-treated industrial wastewater shall
               be discharged directly into the nearest street sanitary sewer main of existing municipal or city sanitary
               sewerage  system  in  accordance  with  the  criteria  set  by  the  Code  on  Sanitation  and  the  National
               Pollution Control Commission.
                       (b)  All  buildings  located  in  areas  where  there  are  no  available  sanitary  sewerage  system
               shall dispose their sewage “Imhoff” or septic tank and subsurface absorption field.
                       (c)  Sanitary and industrial plumbing installations inside buildings and premises shall conform
               to the provisions of the National Plumbing Code.


                       SECTION 904.  Storm Drainage System

                       (a)  Rainwater drainage shall not discharge to the sanitary sewer system.
                       (b)  Adequate provisions shall be made to drain low areas in buildings and their premises.


                       SECTION 905.  Pest and Vermin Control

                       (a)  All buildings with hollow and/or wood construction shall be provided with rat proofing.
                       (b)  Garbage bins and receptacles shall be provided with ready means for cleaning and with
               positive protection against entry of pest and vermins.
                       (c)  Dining rooms for public use without artificial ventilation shall be properly screened.




                       SECTION 906.  Noise Pollution Control

                                                                                                       23