The National Building Code (P.D. 1096)



               railing not less than 1.00 meter high shall be provided.  The entire structure shall be designed to carry
               the  loads  imposed  upon  it:    Provided,  that  the  live  load  shall  be  not  less  than  600  kilograms  per
               square meter.


                       SECTION 1107.  Maintenance and Removal of Protective Devices

                       (a)  Maintenance.    All protective devices shall be properly maintained in place and kept in
               good order for the entire length of time pedestrians may be endangered.
                       (b)  Removal.    Every protective fence or canopy shall be removed within 30 days after such
               protection is no longer required as determined by the Building Official.


                       SECTION 1108.  Demolition

                       (a)  The  work  of  demolishing  any  building  shall  not  be  commenced  until  all  the  necessary
               pedestrian protective structures are in place.
                       (b)   The  Building  Official  may  require  the  permittee  to  submit  plans,  specifications  and
               complete  schedule  of  demolition.    When  so  required,  no  work  shall  be  done  until  such  plans,
               specifications and schedule are approved by the Building Official.