Page 16 - IMER_2021-07_MPT_cat_en_Neat
P. 16

Sph
          Tph
       KOINE 4 Hi-Flow


       High flow continuous cycle mixing pump
                    50 Hz                              60 Hz
        Koine 4 Hi-Flow 400V/50Hz Tph - 6.8 kW  Koine 4 Hi-Flow 230V/60Hz Tph- 6.8 kW
        1106320                           with I-Dust grate
                                          1106004










                    Sph






                    Tph








                               Sph





                       R8 stator and rotor pumping unit and                       Hydraulic system in anti-oxidation brass.
                       turbo mixer as standard. The standard                      Arrangement of the components designed to
                               Tph
                       turbo mixer is essential to improve mixing                 improve water drainage in winter.
                       and ensure the homogeneity of the                          INGX3 self-priming electropump, capable of
                       pumped products. Integrated pressure                       4.5 bar pressure and flow rate up to 2500 l /
                       monitor and connection for Ø 35 F pipe.                    h, with stainless steel cap and brass impeller.



       Description                                              Operation
       High flow continuous cycle mixing pump, suitable for pumping large volumes   The bagged material is poured into the hopper, where a feeding wheel
       of material in bags (up to 220 bags per hour).           fills  the  mixing  chamber  continuously  and  constantly.  The  water
                                                                necessary to obtain the mixture is injected into the mixing chamber by
       Ideal for laying self-levelling screeds in bags with a minimum thickness of   a stainless steel pump.
       2 cm.
                                                                The water flow is kept constant through a particular stabilization system
       Suitable for pumping dry premixed materials:             and controlled by a valve that starts or stops the flow if necessary.
       • Self-levelling cement-based screeds
       • Self-levelling anhydride-based screeds                 The amount of water in the mixture can be viewed in the flow meter and
       • Structural reinforcement mortars                       can be adjusted according to the needs through a micrometric valve.
       • Grout / Core-Filling Grout
                    Sph
       • Cork / polystyrene based insulating screeds            The freshly mixed material is immediately sucked by the “Rotor-Stator”
       • Fireproofing materials                                 pumping system and is mixed a second time passing through the turbo
                                                                mixer. Then it is pushed into the pipe until it reaches the opposite end
       The product must be poured into the hopper of the machine directly from   to be laid.
       the bags.
                                                                Washing is simple, very fast and without water and material spilling
       To limit the dust during use, it is recommended utilizing I-Dust grate item   in the work area. The only area that needs to be cleaned is the one
                    Tph
       1107491, connected to a powerful vacuum cleaner equipped with a cyclone   where the mixture takes place. The unused dry material can remain in
       filter for dust recovery.                                the hopper and be removed if necessary, by opening the appropriate
       (Optional for 1106320 Koine Hi-Flow 400V 50Hz).          discharge plug at the bottom of the hopper.
                                                                Koine 4 Hi-Flow is equipped with safety devices and devices for
                                                                protecting electric motors from overloads with light signals:
                                                                • Correct line / phase presence
                                                                • Overload alarm (magnetothermic intervention)
                                                                • Presence of optimal water pressure
                                                                • Stand-by remote control status
                                                                • Self-resetting thermal protector intervention in the mixing motor