Page 30 - TECHNICAL SPECIFICATION FOR PALM OIL REFINING_rev.1 - Copy_Float
P. 30

OFFER NO. KMIPL/P16E0097R7
                                                      100 TPD PHYSICAL REFINERY AND FRACTIONATION
                                                                                              Page No. 30/69


               Cooling Water Circuit:

               The cooling water circuit comprises water tanks, chiller  unit & plate heat

               exchanger.
               The water of cooling water tank is pumped through the  PHE in order to  cool

               down by outside cooling tower water.  Surplus water flows back to the same

               tank. Water from Cold water tanks is pumped through the evaporator from the
               chilling unit and Surplus water flows back to the tank


               Advantages of Kumar Fractionation System:



               Crystallizers are designed to create a high grade of homogeneity in terms of oil &

               temperature and the small distance between the cooling surface & the oil, which
               gives the following advantages:

                   •  No steady zones in the oil mass during crystallization.

                   •  Uniform crystallization.
                   •  Constant quality of finished product.


               Crystallizers are designed with a higher ratio of cooling surface to oil volume,

               giving the following advantages:

                   •  High cooling capability & hence full control of the oil temperature.
                   •  No undesirable temperature increase during crystallization.
   25   26   27   28   29   30   31   32   33   34   35