Page 27 - TECHNICAL SPECIFICATION FOR PALM OIL REFINING_rev.1 - Copy_Float
P. 27
OFFER NO. KMIPL/P16E0097R7
100 TPD PHYSICAL REFINERY AND FRACTIONATION
Page No. 27/69
Auxiliaries for Refinery
1. Water Cooling and Cold Water Circulation system consists of -
Consists of Dirty Cooling Tower of capacity to cool water 90M /Hour
3
having inlet water temperature 38 0 Centigrade and outlet water
temperature after cooling will be 32 Centigrade
0
Circulating pumps with motor base frame coupling – 3 Nos
Clean Cooling Tower of capacity to cool water 60M /Hour having inlet
3
water temperature 38 Centigrade and outlet water temperature after
0
cooling will be 32 Centigrade
0
Circulating pumps with motor base frame coupling – 2 Nos
Cold Water Distribution and Return Water Pipelines, valves, NRVs etc
complete with Control Panel.
2. Steel structure materials for equipment support, staging, railing, ladder,
working platform etc @ 91 Tons with roofing sheets for refinery.
3. Refined oil packing filling for 5 liters, 10 liters & 20 liters
Filling mode – Automatic
Filling Heads – 2 Nos
Filling speed –
5 ltrs jerry Cans @ 5 fills per minute
10 ltrs jerry cans @ 4 fills per minute
20 ltrs jerry cans @ 2 fills per minute
Pneumatic capping machine – manual
4. Spares for 2 years