            Florida Building Code Sections Related to Termites
            The Florida Building Code became effective March 1, 2002.  This code contains a number
            of provisions that were designed to increase the effectiveness of preventative treatments
            for termites and decrease construction practices that make structures susceptible to
            termite infestation.  The changes were developed by the Termite Work Group consisting
            of representatives of the pest control industry, the building industry, universities, and state
            agencies. The table below lists sections of the Florida Building Code that pertain to termite
            protection and gives a short description of that section.  The actual language of the sections
            referenced below can be seen on the Florida Building Commission’s website.
                         Certificate of Protective     Requires posting of applications - no “final approval”
             104.2.6     Treatment for Prevention      if all applications not made, including vertical barrier
                         of Termites

                                                       Requires posting of consumer notice inside house
                         Notice of Termite
             104.2.7                                   - will inform owner of need to renew contract and
                         Protection
                                                       inspect annually
                         Section 1403 - Veneered       Requires 6 inch space between grade and siding for
             1403.1.6
                         Walls                         termite inspection
                         Protection Against Decay      Requires discharge lines and gutter downspouts to
             1503.4.4
                         and Termites                  terminate at least one foot from foundation
                                                       Requires foundations to have some form of
                         Foundations and Retaining
             1816.1                                    protection from termites (“labeled for use as a
                         Walls - Termite Protection
                                                       preventative treatment to new construction”)
                                                       If soil treatment is used, must be done after
             1816.1.1
                                                       compaction
                                                       If soil treatment is used, disturbed areas must be re-
             1816.1.2
                                                       treated
                                                       If soil treatment is used, forms and traps must be
             1816.1.3
                                                       plastic or metal
                                                       If soil treatment is used, vapor barrier must be
             1816.1.4
                                                       installed
                                                       If soil treatment is used, concrete overpour must be
             1816.1.5
                                                       removed
                                                       If soil treatment is used, applications must also
             1816.1.6                                  be made within one foot of the foundation under
                                                       adjoining slabs
                                                       Soil treatment must be in compliance with DACS
             1816.1.7 Termite Protection
                                                       rules