Progress thus far






                   CBERD has categorized progress so far in three   ¾   Hygrothermal characterization  of Phase   CBERD
                   easy to comprehend categories.                       Change Materials  (PCM); inter-lab

                   1)  Creation of  Knowledge: This  part               comparisons. Development of PCM tiles
                       contains  work which  has  added knowledge       for ceiling and deployment of it in test for
                       into existing pool of knowledge or has created   evaluation.
                       new knowledge and / or technology.  This     ¾   Natural  Exposure  of  Cool  Roofing
                       Includes:                                        Products in India to study the Weathering
                                                                        and Aging  Process:  Protocol  finalization
                      ¾   Model  Predictive Control method for
                          enhanced savings through low-energy           and test runs.
                          radiant cooling.                          ¾   Characterization  of laser-cut  panel

                      ¾   Development of a graduated approach for       that allow deep daylight penetration
                                                                        through test apparatus and evaluation
                          benchmarking,  usable for market-facing
                          deployment activities.                        of technology in India and development
                                                                        of easy to use tool to predict daylight
                      ¾   Development of PoE based blind controls       penetration.
                          for shading, smart luminaire controller; and     Development of algorithms to be included
                          implementation of dual loop mechanism to   ¾
                          control light on task plane.                  in EnergyPlus for calculation of resultant
                                                                        SHGC  in presence of non-coplanar
                      ¾   Enhanced design for energy efficient, lower   shading devices.
                          mass micro-channel heat exchanger from
                          small  unitary HVAC systems,  supported   ¾   Indoor   environmental  performance
                          by industry partner Delphi.                   evaluation of thirteen naturally-ventilated



































                                                                                       Status Report 2015         29